![Toro Z Master Commercial TURBO FORCE 3000 Series Operator'S Manual Download Page 46](http://html1.mh-extra.com/html/toro/z-master-commercial-turbo-force-3000-series/z-master-commercial-turbo-force-3000-series_operators-manual_1132615046.webp)
Installing the Battery
Note:
Position the battery in the tray with the terminal
posts opposite from the hydraulic tank (
).
g032526
Figure 61
Charging the Battery
WARNING
Charging the battery produces gasses that
can explode.
Never smoke near the battery and keep sparks
and flames away from battery.
Important:
Always keep the battery fully charged
(1.265 specific gravity). This is especially
important to prevent battery damage when the
temperature is below 0°C (32°F).
1.
Charge battery for 10 to 15 minutes at 25 to 30
A or 30 minutes at 10 A.
2.
When the battery is fully charged, unplug
the charger from the electrical outlet, then
disconnect the charger leads from the battery
posts (
3.
Install the battery in the machine and connect
the battery cables; refer to
(page 46)
.
Note:
Do not run the machine with the battery
disconnected, electrical damage may occur.
g000960
Figure 62
1.
Positive battery post
3.
Red (+) charger lead
2.
Negative battery post
4.
Black (-) charger lead
Servicing the Fuses
The electrical system is protected by fuses. It requires
no maintenance, however, if a fuse blows check the
component/circuit for a malfunction or short.
1.
The fuses are located on the console to the right
of the seat (
2.
To replace the fuses, pull out on the fuse to
remove it.
3.
Install a new fuse (
g008966
Figure 63
1.
Optional accessory (15 A)
4.
Main (25 A)
2.
Charge (25 A)
5.
Console
3.
PTO (10 A)
46