1
G020713
2
3
Figure 14
1.
Ignition switch
3.
Hour meter
2.
Choke control
4.
Engine Start will only become energized by pressing the
Start button while the Engine Start Enable Condition
is active. The Engine Start Enable Condition becomes
active only when the following Engine Start Enable
Sequence has been performed (Figure 15).
•
Press the START button.
•
Then, press the rotate left button.
•
Then, press the rotate right button.
•
Then, press and hold the START button until the
engine starts.
Note:
There is a time limit of 3 seconds between
each button press. If the next button in the sequence
is not press within 3 seconds of the last button press,
the sequence is aborted and must be started from the
beginning.
Note:
If any button other than the next appropriate
button in the sequence is pressed the sequence is
aborted.
Note:
If the Start button is not pressed within 25
seconds after pressing the Rotate Right button, or any
other button is pressed in this period, the Engine Start
Enable Condition expires
Note:
Engine Start Enable Condition persists for 25
seconds after pressing the Rotate Right button allowing
momentary activation of Engine Start by pressing the
Start button. Pressing the Start button does not extend
this time period—the maximum length of time that the
Start Relay Control can be active is 25 seconds from
pressing the Rotate Right button. The Start button can
be pressed multiple times while Engine Start Enable
Condition is active. After the Engine Start Enable
Condition expires, the Engine Start Enable Sequence
must be performed again in order to energize the Start
Relay Control with the Start button.
Note:
If the sequence is aborted or the Engine Start
Enable Condition expires, normal functionality of the
Rotate Right and Left buttons will return to control
the Chute Motor.
g017705
1
2
3
4
5
6
Figure 15
1.
Rotate nozzle left
4.
Increase blower output
2.
Rotate nozzle right
5.
Engine start
3.
Decrease blower output
(Pressing 3 and 4 together
returns engine to idle)
6.
Engine stop
Important:
Do not engage starter for more than
10 seconds at a time. If engine fails to start allow
30 second cool-down period between attempts.
Failure to follow these instructions can burn out
starter motor.
5.
After the engine starts, move the choke control to the
off position. If the engine stalls or hesitates, move the
choke back to the ON position for a few seconds, then
set the engine speed to the desired setting. Repeat this
as required.
Stopping the Engine
1.
Decrease the engine speed midway between the slow
and fast positions.
2.
Let the engine idle for 20 seconds.
3.
Press the STOP button on the remote control.
4.
If leaving the machine, rotate the key to the OFF
position and remove it from the engine (Figure 14).
15
Summary of Contents for ProForce 44539
Page 30: ...Notes 30...
Page 31: ...Notes 31...