Network VP Satellite Controller
Installation Instructions
Introduction
The Network VP satellite controller is designed for installation on a substantial concrete foundation with imbedded conduit
of various diameters to enable power, field, ground and communication wiring to be routed into the cabinet for connection.
A mounting bolt positioner and basic mounting hardware components are included with each controller. Additional materials
required to complete the installation must be obtained separately. A material list can be compiled by reading through the
instructions completely prior to starting the installation.
CAUTION: For your protection and the safety of the product user, comply with all Caution and Warning
statements within this document. All installation practices must comply with all applicable national and/or local
electrical and construction codes.
Network VP Satellite Radio Module Frequency Setting
The Network VP Satellite Radio module is preprogrammed with 16 usable frequencies. See Frequency Table.
If the 16 preset frequencies are not suitable for the installation area and/or application, the Network VP Satellite radio module
can be programmed with a new frequency. Leave power output setting to low. The procedure to program the narrow-band
radio with a new frequency is similar to the Toro’s Sentinel radio. Use the Sentinel Radio Programming kit P/N 102-2447 for
this procedure.
Note: The Network VP Satellite Radio module channel switches is preset to Channel 1.
To select from the 16 preset frequencies, use the following steps.
1. Detach the radio module from the radio assembly by removing the two
retaining screws. See Figure 1. Remove the front cover of the Network
VP Satellite Radio module to access the channel setting switches. See
Figure 2.
2. Choose the proper channels frequency from the pre-programmed
Frequency Table. Set the channel switches according to the
corresponding channel switches configuration.
3. Replace the Network VP Satellite Radio module front cover.
WARNING
AC POWER TO THE SATELLITE MUST BE TURNED OFF PRIOR TO WORKING INSIDE THE CONTROLLER
CABINET. FAILURE TO COMPLY MAY RESULT IN SERIOUS OR FATAL INJURY DUE TO ELECTRICAL SHOCK
HAZARD.
115V
WARNING
HIGH
VOLTAGE
4
M
A
P
Figure 1
Connect to Programming
Kit Cable
Figure 2
Channel Configuration
RX/TX Frequency
Channel Configuration
RX/TX Frequency
1
463.6125
9
461.7125
2
452.2125
10
461.8375
3
452.2875
11
461-9875
4
456.7875
12
466.4375
5
457.2125
13
466.5375
6
457.5625
14
466.8375
7
461.4125
15
466.9875
8
461.5375
16
469.9000
Frequency Table