Winterization

 

Winterizing the irrigation system is required in freezing climates to prevent damage from water expansion when it 

freezes. Following are three key points for successfully winterizing the system, however, Toro provides a complete 

“Winterization and Pressurization Guide” (P/N 373-0849) that is available from your local Toro Distributor.

• 

Open low point drains, vent high points and allow the system to drain naturally several days prior to using 

compressed air.

• 

Attach compressor to the highest point possible and use the compressed air to force remaining water out of the 

low points and close vents and drains working from high points to low points when clear air is observed.

• 

Regulate compressed air to 50 psi and cycle each sprinkler ONCE until clear.

Arc Adjustment Procedure

 

The FLX35 and FLX55 sprinkler models can be operated in full-circle or part circle operation. In part-circle operation, 

the sprinkler arc can be adjusted from 40°– 330°. When full-circle (360°) operation is selected, the sprinkler will rotate 

in a clockwise direction only. The arc is factory preset at 180°. The left side of the arc, located at the end of the 

counterclockwise rotation, is non-adjustable (fixed). Therefore, all arc adjustments, whether increasing or decreasing, 

will change the right side of the arc, located at the end of the clockwise rotation.

Step 1 –  Using the sprinkler tool, pull the sprinkler riser up from the body. See Figure 2

Step 2 –  Find the sprinkler left stop by rotating the turret counter clockwise until it stops. The left stop indicates the 

fixed stop of the arc. See Figure 3

Step 3 –  Check the left stop alignment with the left most area being irrigated. Adjust 

as follows by ratcheting the riser clockwise or counterclockwise until the 

sprinkler left stop points to the correct area. See Figure 4

 

1. If the left stop falls short of the desired border, rotate the turret 

counterclockwise to the stop, then ratchet the riser until it is aligned with 

the left watering border. See Figure 4

 

2. If the left stop exceeds the border, rotate the turret clockwise to the right 

stop. Continue to advance the turret the same distance that the left stop 

exceeded the border. See Figure 5

Step 4 –  Find the sprinkler right stop by rotating the turret clockwise until it stops. 

See Figure 5

 

Note: If the sprinkler is set at 360° (full-circle), it will rotate clockwise only.

Step 5 –  Adjust the arc while the turret is pointing at the right stop. Hold the 

sprinkler riser firmly while pressing the release on the adjustment band. 

Rotate the turret counterclockwise or clockwise to the desired right stop. See Figure 6

Step 6 –  Activate the sprinkler to check proper arc setting and adjust as necessary.

Figure 2

Figure 3

Figure 4

Figure 5

Figure 6

995-83

Summary of Contents for FLX35 Series

Page 1: ...Series Radius 43 83 13 1 25 3 m Flow Rate 8 2 47 3 GPM 31 179 LPM Trajectory Selectable 15 or 25 Arc Full Circle 360 or adjustable part circle 40 330 Recommended Operating Pressure 65 100 PSI 4 5 6 9...

Page 2: ...9 0 66 24 7 71 29 5 72 32 9 78 39 5 82 42 6 82 46 1 FLX55 Series Performance Chart 25 Front Nozzle Positions Nozzle Set 51 Yellow Nozzle Set 52 Blue Nozzle Set 53 Brown Nozzle Set 54 Orange Nozzle Set...

Page 3: ...pipe thread connections Use of pipe dope or other paste sealants can cause deterioration of the sprinkler body threads Tape should be applied to the male threaded fitting in compliance with the tape m...

Page 4: ...tomatic operation or when performing sprinkler service procedures Direct contact with irrigation spray a failed or improperly installed sprinkler connection or sprinkler components forcibly ejected up...

Page 5: ...the right side of the arc located at the end of the clockwise rotation Step 1 Using the sprinkler tool pull the sprinkler riser up from the body See Figure 2 Step 2 Find the sprinkler left stop by ro...

Page 6: ...N 995 99 to turn the main nozzle assembly Turn the main nozzle assembly clockwise until the angle indicator points towards the right to set 25 trajection Continue turning the main nozzle clockwise unt...

Page 7: ...auses and corrective action are listed below Sprinkler won t rotate Debris wedged between stator and turbine Remove obstruction Drive assembly defective Replace drive assembly Nozzle base assembly def...

Page 8: ...lve seat Remove blockage and if necessary replace valve assembly Damaged piston seal or piston assembly Replace valve assembly Damaged pilot valve discharge seat Clean or replace pilot valve Damaged p...

Page 9: ...ly turn the screen counterclockwise to remove Step 4 Remove the variable stator 16 from riser assembly Step 5 Remove the drive assembly retaining screw 14 and pull the drive assembly 15 using a pair o...

Page 10: ...al tool is not available use snap ring pliers to grasp rib of valve cylinder assembly and pull up and out of sprinkler body Step 3 Reinstall valve assembly using valve insertion tool P N 995 76 for FL...

Page 11: ...Step 7 Remove the retaining nut 18 and washer 17 from the pressure adjuster 11 and pull the pilot valve body assembly out of housing 16 Step 8 Remove diaphragm assembly 15 piston 14 spring 13 traveli...

Page 12: ...NOTES 2015 The Toro Company Irrigation Division www toro com Form Number 373 0859 Rev A...

Reviews: