background image

Precipitation Rate Formulas 

• 

Square-spaced sprinklers in pattern:

GPM of full circle x 96.3

(Spacing)

2

• 

Triangular-spaced sprinklers in 

pattern:

GPM of full circle x 96.3

(Spacing)

2

 (0.866)

• 

Area and flow:

Total GPM of zone x 96.3

Total irrigated           

Square feet of zone

• 

Single row:

GPM of full circle x 96.3

(Spacing) (Scallop)

Sprinkler Spacing Guidelines
• Square Spacing

   

No wind  -  55% of diameter 

    4 mph wind  -  50% of diameter

    8 mph wind  -  45% of diameter 

• Triangular Spacing

   

No wind  -  60% of diameter 

  4 mph wind  -  55% of diameter 

  8 mph wind  -  50% of diameter

• Single-Row Spacing

   

No wind  -  50% of diameter 

  4 mph wind  -  50% of diameter 

  8 mph wind  -  45% of diameter

 Note: 

Designing for zero (0) mph 

wind conditions is not recommended.  

Design for worst wind conditions.  

 

For additional information, refer to 

Toro Technical Data Manual,  

form number 490-1737.

Toro Swing Joints

 

Use Toro swing joints to connect the sprinklers to the lateral/main line pipe.                              
Toro swing joints provide swivel joints that allow the sprinkler body to be easily positioned 

to finished grade and prevents pipe breakage by providing the flexibility to allow downward 

movement if the sprinkler is run over by heavy equipment.
For installation using pipe thread connections (NPT or BSP), use PTFE tape only to seal 

all threaded connections.

CAUTION: Use PTFE tape only for sealing pipe thread connections. Use of pipe dope or 

other paste sealants can cause deterioration of the sprinkler body threads.
Tape should be applied to the male threaded fitting in compliance with the tape manufacturer 

recommendations. Thread the fitting into the mating female threaded fitting in the sprinkler 

body and service tee and tighten securely.
For installation using ACME thread connections, do not apply additional sealant.

CAUTION: ACME fittings incorporate an o-ring seal that requires no additional sealant.

Sprinkler fitting installation - Thread the ACME fitting into the sprinkler body and hand tighten until it stops. No 

additional tightening or loosening is required.

CAUTION: Loosening beyond 270° will result in a thread leak.

Lateral/Mainline pipe installation - Thread the ACME fitting into the lateral/main line service tee and hand tighten until 

it stops, then loosen up to one full turn to ensure flexible movement of the swing joint.

Wire Splices

 

CAUTION: Communication cable or station wire connections will deteriorate when exposed to moisture and earth 

ground causing shorts or open circuits resulting in improper system operation.
All direct burial wire connections must be done with approved waterproof connections installed in compliance with the 

manufacturer specifications. Contact your Toro Golf Distributor for approved waterproof connectors.
Always provide a wire service loop for each splice to ensure sufficient wire is available should future servicing be 

required.

Figure 1

Summary of Contents for FLX35 Series

Page 1: ...Series Radius 43 83 13 1 25 3 m Flow Rate 8 2 47 3 GPM 31 179 LPM Trajectory Selectable 15 or 25 Arc Full Circle 360 or adjustable part circle 40 330 Recommended Operating Pressure 65 100 PSI 4 5 6 9...

Page 2: ...9 0 66 24 7 71 29 5 72 32 9 78 39 5 82 42 6 82 46 1 FLX55 Series Performance Chart 25 Front Nozzle Positions Nozzle Set 51 Yellow Nozzle Set 52 Blue Nozzle Set 53 Brown Nozzle Set 54 Orange Nozzle Set...

Page 3: ...pipe thread connections Use of pipe dope or other paste sealants can cause deterioration of the sprinkler body threads Tape should be applied to the male threaded fitting in compliance with the tape m...

Page 4: ...tomatic operation or when performing sprinkler service procedures Direct contact with irrigation spray a failed or improperly installed sprinkler connection or sprinkler components forcibly ejected up...

Page 5: ...the right side of the arc located at the end of the clockwise rotation Step 1 Using the sprinkler tool pull the sprinkler riser up from the body See Figure 2 Step 2 Find the sprinkler left stop by ro...

Page 6: ...N 995 99 to turn the main nozzle assembly Turn the main nozzle assembly clockwise until the angle indicator points towards the right to set 25 trajection Continue turning the main nozzle clockwise unt...

Page 7: ...auses and corrective action are listed below Sprinkler won t rotate Debris wedged between stator and turbine Remove obstruction Drive assembly defective Replace drive assembly Nozzle base assembly def...

Page 8: ...lve seat Remove blockage and if necessary replace valve assembly Damaged piston seal or piston assembly Replace valve assembly Damaged pilot valve discharge seat Clean or replace pilot valve Damaged p...

Page 9: ...ly turn the screen counterclockwise to remove Step 4 Remove the variable stator 16 from riser assembly Step 5 Remove the drive assembly retaining screw 14 and pull the drive assembly 15 using a pair o...

Page 10: ...al tool is not available use snap ring pliers to grasp rib of valve cylinder assembly and pull up and out of sprinkler body Step 3 Reinstall valve assembly using valve insertion tool P N 995 76 for FL...

Page 11: ...Step 7 Remove the retaining nut 18 and washer 17 from the pressure adjuster 11 and pull the pilot valve body assembly out of housing 16 Step 8 Remove diaphragm assembly 15 piston 14 spring 13 traveli...

Page 12: ...NOTES 2015 The Toro Company Irrigation Division www toro com Form Number 373 0859 Rev A...