background image

Service Procedures ________________________________________________________________

Servicing Sprinkler Mechanism 

1. Remove the cap screw (1) and cap (3).

Note: During reassembly, ensure the cap is correctly installed with the
Toro Logo positioned over the main nozzle (10).

2. Insert hooked end of multi-purpose tool (P/N 996-83) into slot in snap

ring (13). Pull snap ring inward toward sprinkler assembly, then upward
to remove from groove.

Note: During reassembly, ensure snap ring is correctly installed and fully
seated in groove.

3. Insert hooked end of mult-purpose tool into slot provided in the nozzle

base above main nozzle. Pull riser assembly out of body.

4. While pushing seal/retainer assembly (14 and 15) downward to slightly

compress return spring, use a 1/2" nut driver (P/N995-80) to remove
nozzle base lock nut (8). Pull nozzle base assembly from drive assembly
shaft.

5. Slowly release tension from return spring. 

6. Remove the slotted stainless steel washer (7).

7. Three small tabs are provided on the edge of the multi-purpose tool.

Insert tabs into debris filter screen. Holding plastic base of riser
assembly, turn screen counterclockwise to remove.

8. Remove variable stator and stator support from riser assembly.

Note: The stator support is keyed to the riser assembly. During
reassembly, ensure stator support slots engage riser assembly
alignment tabs. Refer to Figure 7 for the location of the alignment tabs.

9. Using a 5/8" nut driver (P/N 995-99), unscrew main nozzle from nozzle

base assembly.

10. Using a 7/16" nut driver (P/N 995-79), unscrew two inner nozzles from

nozzle base assembly. Remove restrictor from one inner nozzle.

11. Pressing only on the ribbed area of drive assembly, push the drive

assembly out of riser assembly as shown in Figure 6

CAUTION: When removing or installing the drive assembly, 

DO NOT press on the threaded shaft or attempt to pull the drive
assembly out of riser assembly. Push on the ribbed areas only!
Failure to comply may cause separation of drive assembly
components.

Note: The drive assembly is keyed to the riser assembly. During
reassembly, position the extra rib of the drive assembly to the right of
either alignment tab of the riser assembly as shown in Figure 7.

12. Thoroughly clean and inspect all parts and replace as necessary.

Reassemble in the reverse order.

8

Figure 6

Alignment Tab

Extra Rib Of
Drive Assy

Alignment Tab

Figure 7

23

22

21

20

19

18

16

15

14 

14

1

2

4

8

9

10

11

12

5

7

6

3

3

Figure 5

WARNING

NEVER STAND OR LEAN OVER THE SPRINKLER WHILE THE IRRIGATION SYSTEM IS BEING FILLED,
DURING MANUAL OR AUTOMATIC OPERATION OR WHEN PERFORMING SPRINKLER SERVICE
PROCEDURES. DIRECT CONTACT WITH IRRIGATION SPRAY, A FAILED OR IMPROPERLY INSTALLED
SPRINKLER CONNECTION OR SPRINKLER COMPONENTS FORCIBLY EJECTED UPWARD UNDER
PRESSURE CAN CAUSE SERIOUS INJURY. 

Summary of Contents for 860S Series

Page 1: ...Circle or Adjustable Part Circle 30 330 Recommended Operating Pressure 50 100 PSI 3 4 6 9 bar Minimum Pressure 40 PSI 2 8 bar Maximum Pressure 150 PSI 10 3 bar Precipitation Rate Minimum 0 39 hr 9 9...

Page 2: ...71 36 1 71 80 18 4 57 24 1 65 26 7 67 32 3 71 38 9 77 40 4 77 42 5 77 47 1 77 100 20 6 60 27 0 69 29 9 71 36 3 77 43 7 81 45 4 81 47 8 83 52 9 83 Radius shown in feet Sprinkler radius of throw per ASA...

Page 3: ...ble 1 for proper application Note Wire length data provided in Table 1 is the sum of the station and common wire legs See example in Figure 2 2 Attach control wires to solenoid leads using an approved...

Page 4: ...ts do not compress air and then relieve it bleed the air continuously while filling the system 3 After water has filled all lines and all air is removed remove the quick coupler keys 4 Table 2 Hydraul...

Page 5: ...stment is completed Pilot Valve Operation Electric Models Only _______________________________________________ The main function of the pilot valve is to control the operation of the main valve locate...

Page 6: ...b Nozzle orifice damaged Replace nozzle c Low operating pressure Determine why system overloaded and correct Main Valve PROBLEM POSSIBLE CAUSE CORRECTIVE ACTION VALVE WON T CLOSE a Continuous 24 VAC t...

Page 7: ...refer to Controller Service Manual SPRINKLER WEEPING a Damaged or blocked valve seat Slow leak in valve Remove blockage and if necessary replace valve assembly b Damaged piston seal or piston assembl...

Page 8: ...support slots engage riser assembly alignment tabs Refer to Figure 7 for the location of the alignment tabs 9 Using a 5 8 nut driver P N 995 99 unscrew main nozzle from nozzle base assembly 10 Using a...

Page 9: ...n carrier as shown Locate position of communication tube in bottom of sprinkler body and orient insertion tool accordingly Insert tool straight down into sprinkler body aligning bosses on t handle wit...

Page 10: ...ed Parts Breakout Book form number 368 0044 for service part numbers Flushing Sprinkler ______________________________________________________________ 1 With sprinkler operating carefully step down on...

Reviews: