Hydraulic System
Maintenance
Servicing the Hydraulic
System
Hydraulic Fluid Type:
Toro
®
HYPR-OIL
™
500 hydraulic
oil
Hydraulic System Fluid Capacity:
4.7 L (5 US qt)
Important:
Use the fluid specified. Other fluids could
damage the system.
Checking the Hydraulic Fluid
Service Interval:
After the first 8 hours
Every 500 hours
Note:
Check the hydraulic fluid level when the fluid is cold.
1.
Position the machine on a level surface.
2.
Disengage the power takeoff (PTO) and shut off the
engine.
3.
Wait for all moving parts to stop and set the parking
brake before leaving the operating position.
4.
Clean the area around the cap and the filler neck of the
hydraulic tank (
).
Figure 71
1.
Hydraulic-tank cap
2.
Fill level
5.
Remove the cap from the filler neck (
).
Note:
Look inside to check the fluid level in the
reservoir.
6.
Add fluid to the reservoir until it reaches the fill level.
7.
Install the cap on the filler neck.
WARNING
Hydraulic fluid escaping under pressure can
penetrate skin and cause injury.
•
If hydraulic fluid is injected into the skin,
it must be surgically removed within a few
hours by a doctor familiar with this type
of injury. Gangrene may result if this is
not done.
•
Keep your body and hands away from
pinhole leaks or nozzles that eject
high-pressure hydraulic fluid.
•
Use cardboard or paper to find hydraulic
leaks.
•
Safely relieve all pressure in the hydraulic
system before performing any work on the
hydraulic system.
•
Make sure that all hydraulic-fluid hoses
are in good condition, and all that the
hydraulic connections and fittings are tight
before applying pressure to the hydraulic
system.
47