Maintenance
26
POTENTIAL HAZARD
•
If you leave the key in the ignition switch, someone could start the engine.
WHAT CAN HAPPEN
•
Accidental starting of the engine could seriously injure you or other bystanders.
HOW TO AVOID THE HAZARD
•
Set the parking brake and remove the key from the ignition switch before you do any
maintenance.
Air Cleaner
Service Interval/Specification
Clean the air filter cartridge after every 25 operating
hours. Service it more often (every few hours) if
operating conditions are extremely dusty or sandy.
Replace the cartridge after every 100 operating
hours, or yearly.
Removing the Air Cleaner Cartridge
1.
Unlock the clamps and remove the cover.
2.
Remove the cartridge from the air cleaner body.
Figure 24
1.
Air cleaner body
2.
Cartridge
3.
Cover
4.
Clamps
Cleaning the Air Filter Cartridge
Clean the cartridge by tapping gently on its end with
the handle of a screwdriver. Replace the cartridge if
it is very dirty or damaged.
Installing the Air Filter Cartridge
1.
Install the cartridge in the body.
2.
Install the cover and lock the clamps.