25
CONTROLS
41442 PTO PUMP
RATCHET VALVE HANDLE:
Opens and closes
the Ratchet Valve, starting or stopping flow to
Booms.
PRESSURE ADJUST VALVE HANDLE:
Controls
spray pressure. Turn clockwise to decrease
pressure and counterclockwise to increase
pressure.
PRESSURE GAUGE:
Shows spray pressure when
Ratchet Valve is open. Shows deadhead pressure
when the Ratchet Valve is closed.
3
2
1
FIG. 16
1. Ratchet Valve
3. Pressure Adjust Valve
Handle
Handle
2. Pressure Gauge
AGITATOR VALVE HANDLE
: Opens and closes
the Agitator Valve to activate, adjust or stop the
agitation of the spray solution in the Tank.
SUCTION VALVE HANDLE
: Opens and closes
the Suction Line Valve. Close during maintenance
to the Suction Line Strainer or Centrifugal Pump.
1
2
3
LEFT BOOM SHUTOFF VALVE HANDLE:
Starts
or stops flow to left Boom.
RIGHT BOOM SHUTOFF VALVE HANDLE:
Starts
or stops flow to right Boom.
2
FIG. 18
1. Left Boom Shutoff
2. Right Boom Shutoff
Valve (open)
Valve (open)
1
FIG. 17
1. Suction Valve Handle
3. Suction Strainer
(open)
2. Agitator Valve Handle
(open)
Summary of Contents for 41440
Page 30: ...30 Helping you put quality into...