Reelmaster 7000−D
Page 6 − 20
Electrical System
Troubleshooting
CAUTION
Remove all jewelry, especially rings and
watches, before doing any electrical trouble-
shooting or testing. Disconnect the battery
cables unless the test requires battery voltage.
For effective troubleshooting and repairs, there must be
a good understanding of the electrical circuits and com-
ponents used on this machine.
If the machine has any interlock switches by−passed,
reconnect the switches for proper safety and trouble-
shooting.
Use the InfoCenter Display to test Toro Electronic Con-
troller (TEC) inputs and outputs when troubleshooting
an electrical problem on your Reelmaster 7000−D (see
Using the InfoCenter Display to Test TEC Inputs and
Outputs in this chapter).
Operator Advisories
If one or more Toro Electronic Controller (TEC) inputs
are not in the correct position to allow certain machine
operations, or are malfunctioning, the fault indicator will
illuminate and an advisory screen will appear on the
InfoCenter Display (Figs. 20 and 21). Each advisory
screen has three elements: the advisory number/code,
the advisory description, and the advisory qualifier.
An advisory qualifier denotes the condition(s) that
triggered the advisory and provides instruction on elimi-
nating the advisory. An operator advisory may involve
one or more advisory qualifier. Typically, an advisory can
be eliminated by changing the position of the operator
control(s) referenced by the advisory qualifier. Once the
first qualifier displayed is satisfied, any additional quali-
fiers that remain to be satisfied will appear in the opera-
tor advisory screen individually.
Operator advisory numbers/codes, descriptions, and
conditions/actions are listed in Table 1
Possible advisory qualifiers are listed in Table 2
1. Fault
indicator
2. Advisory
number/code
3. Advisory
description
4. Advisory
qualifier
Figure 20
ADVISORY #162
Denied
H
L
OPERATOR ADVISORY
2
3
4
1
SCREEN
(MULTIPLE ADVISORY QUALIFIERS)
OPERATOR ADVISORY SCREEN
1. Fault
indicator
2. Advisory
number/code
3. Advisory
description
4. First fault qualifier
5. Second fault qualifier
Figure 21
ADVISORY #160
Start Denied.
or
ADVISORY #160
Start Denied.
− FOLLOWED BY −
2
3
4
1
Summary of Contents for 03781
Page 1: ...Form No 15214SL Rev D Reelmaster 7000 D Models 03780 A and 03781 Original Instructions EN ...
Page 4: ...NOTES _ ...
Page 6: ...Reelmaster 7000 D This page is intentionally blank ...
Page 8: ...Reelmaster 7000 D This page is intentionally blank ...
Page 10: ...Reelmaster 7000 D This page is intentionally blank ...
Page 16: ...Reelmaster 7000 D Page 1 6 Safety This page is intentionally blank ...
Page 40: ...Reelmaster 7000 D Page 3 18 Yanmar Diesel Engine This page is intentionally left blank ...
Page 70: ...Reelmaster 7000 D Page 4 24 Kubota Diesel Engine This page is intentionally blank ...
Page 80: ...Reelmaster 7000 D Hydraulic System Page 5 10 This page is intentionally blank ...
Page 226: ...Reelmaster 7000 D Hydraulic System Page 5 156 This page is intentionally blank ...
Page 230: ...Reelmaster 7000 D Page 6 4 Electrical System This page is intentionally blank ...
Page 337: ...Reelmaster 7000 D Page 8 3 Chassis This page is intentionally blank Chassis ...
Page 349: ...Reelmaster 7000 D Page 8 15 Chassis This page is intentionally blank Chassis ...
Page 354: ...Reelmaster 7000 D Page 8 20 Chassis This page is intentionally blank ...
Page 440: ...Reelmaster 7000 D Universal Groomer Optional Page 11 20 This page is intentionally left blank ...
Page 459: ...Page 12 19 Reelmaster 7000 D Engine Wire Harness Drawing Model 03780 Yanmar Engin ...
Page 461: ...Page 12 21 Reelmaster 7000 D Engine Wire Harness Drawing Model 03781 Kubota Engine ...
Page 463: ...Page 12 23 Reelmaster 7000 D Seat and Console Wire Harness Drawing Model 03780 30781 ...