3.5.3 Connection and inspection procedure
See table below
Connect general electrical
installation supply to
machine
Switch off general electrical
installation supply
no
Section acc. to ASE recommendation 50 mm
2
or
to local regulations
Mains
Machine inlet
terminal
strip
See Fig. 314
L1
L2
L3
L1
L2
L3
Switch on main machine
switch QS0
Check voltage at the
service socket XS18
yes
See Fig.
311,
312
230V+/–10%
or US socket
100V–110V?
The machine is correctly installed
yes
Mains
380V to 420V/50Hz or
440V to 460V/60Hz?
After connecting the autotransformer
to the machine, follow the procedure.