Tornatech GT-FluxFP Operating Instructions Manual Download Page 15

15

Tornatech - GT-FluxFP

DESCRIPTION CODE

DESCRIPTION CODE

GTFluxFP -  01

-

1

FM Approved

2

Model (from table on page 16)

Summary of Contents for GT-FluxFP

Page 1: ...ERATING INSTRUCTIONS Tornatech GT FluxFP IMPRINT All rights reserved Any reproduction or usage without written authorisation of Tornatech Inc even partial content is strictly prohibited Subject to change without notice Copyright 2019 by Tornatech Inc ...

Page 2: ...ions from the manufacturer 4 2 DEVICE DESCRIPTION 5 2 1 Scope of delivery 5 2 2 Nameplate 6 3 INSTALLATION AND MODE OF OPERATION 7 3 1 Installation notes 7 3 2 Installation instructions 7 3 3 Mode of operation 9 4 START UP 10 5 TECHNICAL DATA 12 5 1 Dimensions and weights 13 6 DESCRIPTION CODE 15 7 SERVICE 17 7 1 Storage 17 ...

Page 3: ... Warning The operator of these measuring devices is solely responsible for the suitability intendeduseandcorrosionresistanceoftheselectedmaterials It must be particularly ensured that the materials selected for the wetted parts of the flowmeter are suitable for the process media to be measured The manufacturer is not liable for any damage resulting from improper or unintended use of these devices ...

Page 4: ...ch changes The responsibility that the instruments are suitable for the particular application rests solely with the operator Tornatech Inc assumes no liability for the consequences of misuse modifications or repairs that were carried out by the customer without prior consultation In case of a complaint the contested elements must be cleaned of hazardous substances and to be returned to the manufa...

Page 5: ... FluxFP DEVICE DESCRIPTION 2 DEVICE DESCRIPTION 2 1 Scope of delivery Orifice plate flowmeter GT FluxFP Operating instructions Certificate partially optional Replacement gaskets not shown here Fig 1 Scope of delivery ...

Page 6: ...h GT FluxFP DEVICE DESCRIPTION 2 2 Nameplate Description code Order code Nominal size and process connection Flow range USGPM Flow range LPM Fig 2 Nameplate bypass meter Turbo Lux 3 Fig 3 Nameplate orifice plate ...

Page 7: ...l number of the device is indicated Unpack the unit carefully to avoid damage Check the completeness of the delivery against the packing list Check the name plate if the delivered flow meter according to your order 3 2 Installation instructions Installation of the orifice plate Before and after the orifice plate a straight calming section is provided as a function of the nominal diameter D With an...

Page 8: ...r T piece pipe is mounted be fore where at least 5 x D must be available as a straight inlet section directly in front of the orifice plate fig 5 Fig 5 Inlet path and outflow zone An inlet path of 5 x D requires a mounted quarter pipe before When using valves fittings before the orifice plate an inlet path of min 10 x D is always required The outflow zone has to be min 2 x D fig 5 ...

Page 9: ...to prevent the escape of liquids The meter is plugged and screwed with a nut fig 9 pos 9 It must always be mounted vertically so that the float fig 9 pos 4 can move freely in the tube About foreign bodies that have come behind the filter must be removed see 7 2 The tightening of the nut or the cap should be done by hand as possible The threads must for example be slippery by fat To avoid air strik...

Page 10: ...ges that could damage the bypass meter Reference point Fig 8 Rotation bypass meter When the bypass meter is commissioned or set into operation bubbles of air will initially accumulate at the top part which must be removed For this purpose the union nut fig 9 pos 9 must be somewhat loosened during operation and the device must be rotated by 360 so that the air bubbles can escape Then the bypass met...

Page 11: ...800 500 5 6 DN 150 750 300 1 500 200 4 1 130 5 650 1 000 5 6 DN 150 1 000 400 2 000 200 4 1 500 7 500 1 000 5 6 DN 150 1 250 500 2 500 500 5 1 900 9 500 1 000 5 8 DN 200 1 500 600 3 000 500 5 2 200 11 000 2 000 4 8 DN 200 2 000 800 4 000 500 5 3 000 15 000 2 000 4 8 DN 200 2 500 1 000 5 000 1 000 5 3 800 19 000 2 000 4 8 DN 200 3 000 1 200 6 000 1 000 5 4 500 22 500 2 000 4 10 DN 250 3 500 1 400 7...

Page 12: ...19 1 mm 10 DN 250 grooved ends Ø273 0 mm 12 DN 300 grooved ends Ø323 9 mm PN 16 232 psig 64 bar 928 psig for 5 min FM Measuring accuracy 2 0 of full scale value FM Application conditions Temperature limit Medium 4 C to 50 C 39 F to 122 F Water Design Material Orifice plate 2 DN 50 4 DN 100 6 DN 150 12 DN 300 Differential pressure tube Float Bypass orifice Filter Seal Housing tube in stainless stee...

Page 13: ... FluxFP orifice plate and bypass meter Drawing and dimensions 2 DN 50 4 DN 100 Fig 10 GT FluxFP orifice plate Drawing and dimensions 6 DN 150 12 DN 300 Housing tube Bypass meter Measuring tube Float Bypass orifice Differential pressure O Ring Screw cap Cap O Ring Seal Filter ...

Page 14: ...14 110 10 DN 250 166 6 535 273 0 10 750 8 5 18 739 12 DN 300 192 7 559 323 9 12 750 11 0 24 251 Nominal size Ø D Min thickness mm inch min mm inch max mm inch 2 DN 50 60 3 2 375 2 6 0 102 3 6 0 142 2 DN 65 73 0 2 875 2 6 0 102 2 9 0 114 2 DN 65 76 1 3 000 2 6 0 102 2 9 0 114 3 DN 80 88 9 3 500 2 9 0 114 4 0 0 157 4 DN 100 114 3 4 500 3 2 0 126 4 5 0 177 6 DN 150 165 1 6 500 4 0 0 157 5 0 0 177 6 D...

Page 15: ...15 Tornatech GT FluxFP DESCRIPTION CODE 6 DESCRIPTION CODE GTFluxFP 01 1 FM Approved 2 Model from table on page 16 ...

Page 16: ...00 1 500 1 130 5 650 X 0XM0 6 DN 150 Ø165 1 1 000 400 2 000 1 500 7 500 X 0XN0 6 DN 150 Ø165 1 1 250 500 2 500 1 900 9 500 X 0KK0 6 DN 150 Ø168 3 500 200 1 000 760 3 800 X 0KL0 6 DN 150 Ø168 3 750 300 1 500 1 130 5 650 X 0KM0 6 DN 150 Ø168 3 1 000 400 2 000 1 500 7 500 X 0KN0 6 DN 150 Ø168 3 1 250 500 2 500 1 900 9 500 X 0LP0 8 DN 200 Ø219 1 1 500 600 3 000 2 200 11 000 X 0LQ0 8 DN 200 Ø219 1 2 00...

Page 17: ...7 SERVICE 7 1 Storage Store the emptied device in a dry and dust free place Keep away from direct and perma nent sun and heat The storage temperature range is 20 to 60 C 4 F to 140 F Keep away from direct external load to the device ...

Page 18: ...Canada Tel 1 514 334 0523 Toll free 1 800 363 8448 Europe Tornatech Europe SPRL Wavre Belgium Tel 32 0 10 84 40 01 Middle East Tornatech FZE Dubai United Arab Emirates Tel 971 0 4 887 0615 Asia Tornatech Pte Ltd Singapore Tel 65 6795 8114 Tel 65 6795 7823 www tornatech com ...