background image

Tornado

Operation and Maintenance Manual

For Commercial Use Only

Model PG7435 Pro-Glazer H13-24

Catalog No.

97435

See L7435DCP for Parts List

Effective 1/16/06

Form No. L7435DC  Revised 01/06  

¤

2006 Tornado

£

 Industries   All rights reserved.

TORNADO

®

 INDUSTRIES

7401 W. LAWRENCE AVENUE

CHICAGO, IL 60706

(708) 867-5100 FAX (708) 867-6968

www.tornadovac.com

Summary of Contents for 97435

Page 1: ...PG7435 Pro Glazer H13 24 Catalog No 97435 See L7435DCP for Parts List Effective 1 16 06 Form No L7435DC Revised 01 06 2006 Tornado Industries All rights reserved TORNADO INDUSTRIES 7401 W LAWRENCE AV...

Page 2: ...NAL ENGINE SIZE CC 390 ENGINE HP 13 All specifications are subject to change without notice TABLE OF CONTENTS Standard Warranty 3 Safety Instructions 4 5 Operating Instructions 6 Starting Procedure 6...

Page 3: ...KMR 1250 and KMR 1700 are 24 months parts 6 months labor OR 1000 hours of operation whichever comes first Warranties on the 75 140 90 140 are 24 months parts 12 months labor OR 1 000 hours of operati...

Page 4: ...frequented by the public the Tornado Co suggests to avoid inhaling exhaust flames and never run the engine in a closed building or confined area without proper ventilation Although LPG burns more effi...

Page 5: ...he balance and may cause motor overload x Pad holders and brushes must be properly maintained to insure maximum cleaning results x To avoid fire do not use with a flammable or combustible liquid to cl...

Page 6: ...cessary Replace oil cap If the oil is low add API Class SG or SH oil having a SAE viscosity grade appropriate for the expected temperatures as indicated in the Engine Operators Manual The machine is s...

Page 7: ...ad lock nut while gripping the pad and pad driver Position a new pad concentric with the pad driver and retighten with the pad lock nut To remove the pad driver first make sure the oil cap is tightly...

Page 8: ...G HAIR high speed burnishing pad The spray buff solution should be applied to the floor ahead of the machine Do not run the machine into the spray or mist of the spray buff solution DAMP BUFFING Use 3...

Page 9: ...etighten its bolt The tensioner should provide the belt with a 0 16 inch belt deflection when a force of 2 pounds is applied against outside of belt Turn machine upright immediately after the service...

Page 10: ...d Dirty air filters Hard to Start Spark plug or head bolts loose Blown head gasket Insufficient vacuum Coil air gap needs adjusting Low oil Battery low Will Not Start No fuel Blown head gasket Insuffi...

Reviews: