background image

9

54

1

20068

1/4” F Bulkhead Fitting

55

1

20070

90 Deg. 1/4”MPT X 1/2”Barb

56

1

20071

3/8”MPT X 1/2”Barb

57

As Reqd

20072

Hose

59

2

20074

3/8”Barb X 3/8”MPT

60

As Reqd K63903240 Hose

61

1

22189

Gage-Pressure

62

1

24520

1/4”MPT X 3/8”MPT Nipple

63

1

24521

200-500 PSI Regulator Valve

64

1

24522

Vacuum Hose Adapter

65

1

24523

Use 14881—Fitting-Brass Nipple ¼” FPT x ¼” QC

66

1

24524

Latch Assembly

67

1

24525

Exhaust Adapter

68

1

24526

Water Filter

69

1

22007

Kit-High Pressure Hose

( ) ITEM NOT SHOWN

Troubleshooting Guide

SYSTEM

PROBLEM

POSSIBLE CAUSE

REMEDY

Vacuum
System

No Vacuum /
Weak
Vacuum

  Vac tank full

  Float shut-off screen dirty

  Float ball stuck

  Damaged or loose vac hose

  Dump valve open

  Access lid not sealed

  Vac hose clogged

  Air intake grid clogged

  Leak in recovery tank

 Empty 

tank

  Spray off screen

  Tap float and clean

  Attach or replace

 Close 

valve

 Replace 

gasket

 Clear 

debris

 Clean

  Clean and dry area and silicone

No Power to
Pump or
Vac motor

  Unit not plugged in

  Switch not "ON"

  Building circuit overloaded

  Wiring connections loose

  Plug In machine

 Check 

switches

 Reset 

circuit

  Unplug machine, check for loose wires

Electrical
System

Burning smell

  Vac motor hung up

  Pump motor hung up

  Replace vac motor

  Release pressure on hose and jog or

replace pump

Pumping
System

No Flow /
Weak Flow

  No power to pump

  Jet on wand clogged

 H2O 

filter 

clogged

  Debris in solution tank covering inlet

  Hose kinked or loose

 Pump 

failed

 Check 

electrical

  Clean jet filter

 Clean 

filter

  Clear debris, do not use powder soaps

 Check 

hoses

 Replace 

pump

Summary of Contents for 2-500H Professional

Page 1: ...GO IL 60706 708 867 5100 FAX 708 867 6968 www tornadovac com Tornado Operation Maintenance Manual For Commercial Use Only 12 Gallon CarpetRinser Dryers Catalog Model 98245 2 500 H Professional L8245BA...

Page 2: ...AGE 6 ACCESSORIES PAGE 7 PARTS LIST PAGE 8 TROUBLESHOOTING PAGE 9 FRONT VIEW PAGE 10 FRONT VIEW CLOSE UP PAGE 11 TOP RECOVERY TANK PAGE 12 RECOVERY TANK PARTS PAGE 13 SOLUTION TANK PAGE 14 SIDE VIEW B...

Page 3: ...Warranty on batteries and chargers One year pro rated Effective January 1st 2001 Terms subject to change without notice 1 Windshear Blower Dryer Insulation Blowers T191 T201 CV 30 CV 38 CW 50 CW 100...

Page 4: ...n using unit near children Do not leave unit outdoors or in extreme heat or cold Harsh weather elements will damage components and void warranty Lift using only the appropriate handles Always wear app...

Page 5: ...rong red then the plugs are on two different circuits and the unit should run properly If the light does not come on is a very faint red color or flickers on and off then the unit is on the same circu...

Page 6: ...pment after use Clean all filters and dump valve 2 The solution system has one filter located in the solution tank and high pressure machines 200psi and higher have an in line filter in the pump compa...

Page 7: ...7 ACCESSORIES FOR ALL MODELS...

Page 8: ...s Reqd 20023 Washer 21 2 20024 Bolt Top Tank 22 6 20025 Bolt Motor Manifold 23 4 20026 Bolt Tank Strap 24 2 20027 Strap Tank 25 1 20028 Screen Float Assembly 26 1 20029 Clamp Vac Hose 27 1 20030 Ball...

Page 9: ...vac hose Dump valve open Access lid not sealed Vac hose clogged Air intake grid clogged Leak in recovery tank Empty tank Spray off screen Tap float and clean Attach or replace Close valve Replace gas...

Page 10: ...10 FRONT VIEW...

Page 11: ...11 FRONT VIEW CLOSE UP...

Page 12: ...12 TOP RECOVERY TANK...

Page 13: ...13 RECOVERY TANK PARTS...

Page 14: ...14 SOLUTION TANK...

Page 15: ...15 SIDE VIEW BOTTOM ASSEMBLY...

Page 16: ...16 REAR VIEW BOTTOM ASSEMBLY...

Page 17: ...17 CONNECTIONS SOLUTION TANK...

Page 18: ...18 INTERNAL VIEW WITH COOLING BOTTOM ASSEMBLY...

Page 19: ...19 INTERNAL VIEW WITH HEATER BOTTOM ASSEMBLY...

Page 20: ...20 VACUUM MOTORS...

Page 21: ...21 INTERNAL VIEW OF FITTINGS BOTTOM ASSEMBLY...

Page 22: ...22 INTERNAL VIEW BOTTOM ASSEMBLY...

Page 23: ...23 ELECTRICAL PLUMBING SYSTEM...

Reviews: