55
Check list for the garage door operator
W-800
Check list for the garage door operator
Confi rm features at start-up with a check mark.
No.
Equipment
present
Features to be tested
Remarks
1.0 Garage door
1.1
Manual operation of the door
Smooth running
1.2
Fastenings/connections
State/Seat
1.3
Pivots/joints
State/Lubrication
1.4
Track rollers/track roller holders
State/Lubrication
1.5
Seals/sliding contact strips
State/Seat
1.6
Door frame/door guide
Alignment/Fastening
1.7
Door leaf
Alignment/State
2.0 Weight
counterbalance/safe opening
2.1
Springs
State/Seat/Setting
2.1.1
Spring strips
State
2.1.2
Spring break device
State/Data plate
2.1.3
Safety elements (spring connector,…)
State/Seat
2.2
Wire cables
State/Seat
2.2.1
Mounting
State/Seat
2.2.2
Cable drum
2 Safety windings
2.3
Fall protection
State
2.4
Concentricity of T-shaft
State
3.0 Operator/controls
3.1
Operator/sliding rail/bracket
State/Fastening
3.2
Electrical cables/connections
State
3.3
Emergency release
Function/State
3.4
Control devices, push-button/hand transmitter
Function/State
3.5
Limit stop
State/Position
4.0 Safeguarding of crush and shearing zones
4.1
Force limit
Stops and reverses
4.2
Protection against lifting of persons
Door leaf stops at 20 kg
4.3
Site conditions
Safely distances
5.0 Other devices
5.1
Latching/lock
Function/State
5.2
Wicket
Function/State
5.2.1
Wicket door contact
Function/State
5.2.2
Door closer
Function/State
5.3
Traffi c light control
Function/State
5.4
Photoelectric sensors
Function/State
5.5
Closing edge safety device
Function/State
6.0 Documentation of the operator/owner
6.1
Data plate/CE marking
complete/readable
6.2
Door system’s declaration of conformity
complete/readable
6.3
Installation, Operation and Maintenance Instructions
complete/readable