4: INSTALLATION
4. If applicable, verify the optional Jog Shuttle:
l
Press any axis button on the Jog Shuttle —
X
,
Y
,
Z
, or
A
— to select an axis.
Figure 4-10: Functions on the optional Jog Shuttle.
From the PathPilot interface, on the
Main
tab, the
corresponding green
Axis
light comes on.
Figure 4-11: Axis lights.
l
Turn the
Jog Shuttle Ring
in any direction to move the
selected axis, then turn it in the opposite direction to
reverse the direction.
4.12.5 Testing Plasma Source Control
1. Using the "Connectors Reference" (page 45) verify that
the Hyperthem control cable is connected to the correct
spot on the rear of your electrical cabinet.
2. Jog the torch to a location several inches above the
water table so that you can safely test the arc.
3. Activate the plasma source and create a pilot arc by
pressing the
TEST TORCH
button in PathPilot.
4. Verify that your plasma source activates and creates a
pilot arc (you may have to press the button twice to
bypass the "warning puff" function on some plasma
sources).
5. While the pilot arc is active, watch the "Torch Voltage"
readout at the bottom of your control screen.
You should see an open-circuit voltage of above 100V. If
you do not see a voltage reading, follow the "Voltage
Feedback" (page 68) section of the Troubleshooting
guide.
©Tormach® 2020
Specifications subject to change without notice.
Page 39
UM10720: 1300PL Operator's Manual (Version 0820B)
For the most recent version, see tormach.com/support
Summary of Contents for 1300PL
Page 1: ...Original Instructions OPERATOR S MANUAL Version 0820B ...
Page 10: ......
Page 24: ......
Page 50: ......
Page 58: ......