The unwired version with the Checker board in
the remote enclosure should be installed
according to the following additional
instructions.
1. Remove the back panel to access the blower
motor (see Figure 1 SDF-4 Phantom View).
2. Install and wire the motor starter, control
circuit transformer, and other motor control
components as required (see Figure 19
Unwired with Checker Board in Remote
Enclosure).
3. Wire the motor to the motor starter using
the factory installed conduit between the
motor connection box and the electrical
compartment.
NOTE
• Explosion vent SDF collectors do not
contain an electrical compartment or
internal conduit for wiring.
• Two 3/4" couplings are provided on
the outside of the collector for
electrical wiring access (see Figure 15
SDF-4 with Explosion Vents Phantom
View).
• All wiring on these units must be done
by a qualified electrician according to
local codes.
Figure 19
Unwired with Checker Board in Remote Enclosure
Access for Wiring
to Motor
Wiring to
Temperature Sensor
Terminal Strip
Mounting
Panel for
Motor Starter
(By others)
High Pressure
Fitting
Door Shown in
Open Position
Low Pressure Fitting
Wiring to Solenoid
Valves