7
SYSTEM AIR PURGE PROCEDURE
IMPORTANT: BEFORE FIRST USE
Perform the following Air Purge Procedure to
remove any air that may have been introduced into
the hydraulic system as a result of product shipment
and handling. This step is to be completed without
any weight on the jack.
All numbers in parenthesis () refer to the index
number from the parts breakdown.
1. Connect air supply inlet to air source.
2. Refer to picture when performing this step.
Take off the screw located on handle piece 1;
Attach handle pieces 1 and 2 making sure to
align the holes on both sections. Reinsert the
screw and tighten. Check to that handle is in
perfect alignment with internal lowering valve
mechanism. (Handle lowering mechanism must
be in perfect alignment or release mechanism will
not work.).
3. Attach handle position release rod.
4. Check movement of both Pieces before next step.
5. Insert the handle (37) into handle sleeve (45) and
affix the handle (37) using bolt (46).
6. Carefully place the adapter plate (40) onto the
handle (37) with U-bolts (44), washer (43),
lock washer (42) and nut (41). Place extension
adapters on the plate and secure with spring clips
(39).
13
10
9
8
22
2
26
air source
37
45
46
Do not lift or carry jack by handle. Handle could
dislodge and jack may fall, resulting in possible
injury or property damage.
WARNING!
39
38
37
41 42 43
40
44