REG[2Eh] Font Write Type Setting Resister
Bit
Description
Default
Access
7-6
Font Size Setting
Full
Size
Half-Size
Variable
Width
00b
16x16
8x16
NX16
01b
24x24
12x24
NX24
1Xb
32x32
16x32
NX32
Note:
The font width indicated by “N” depends on the
character code of the FONT.
0
RW
5-0
Font to Font Width Setting
00h : Font width off
01h : Font to Font width = 1 pixel
02h : Font to Font width = 2 pixels
:
:
3Fh : Font to Font width = 63 pixels
0
RW
REG[2Fh] Serial Font ROM Setting
Bit
Description
Default
Access
7-5
GT Serial Font ROM Select
000b: GT21L16TW / GT21H16T1W
001b: GT30L16U2W
010b: GT30L24T3Y / GT30H24T3Y
011b: GT30L24M1Z
100b: GT30L32S4W / GT30H32S4W
0
RW
4-2
FONT ROM Coding Setting
For specific GT serial Font ROM, the coding method must
be set for decoding.
000b: GB2312
001b: GB12345/GB18030
010b: BIG5
011b: UNICODE
100b: ASCII
101b: UNI-Japanese
110b: JIS0208
111b: Latin/Greek/ Cyrillic / Arabic
0
RW
1-0
A
SCII
/
Latin/Greek/ Cyrillic / Arabic
Latin
A
SCII
Latin/Greek/
Cyrillic
Arabic
Latin
00b
Normal
Normal
NA
01b
Arial
Variable
Width
Presentation
forms-A
10b
Roman
NA
Forms-B
11b
Bold
NA
NA
0
RW
REG[30h] Horizontal Start Point 0 of Active Window (HSAW0)
Bit
Description
Default
Access
7-0
Horizontal Start Print of active Window [7:0]
0
RW
REG[31h] Horizontal Start Point 1 of active Window (HSAW1)
Bit
Description
Default
Access
7-2 NA
0
RO
1-0
Horizontal S
t
art Point of Active Window [9:8]
0
RW
REG[32h] Vertical Start Point 0
o
f Active Wind
o
w (VSAW0)
Bit
Description
Default
Access
7-0
Vertical Start Point of Active Window [7:0]
0
RW