![Topward 6302A, 6302AR, 6302D, 6302DR, 6303A, 6303AR, 6303D,6303DR, 6306A, 6306AR, 6306D, 6306DR, 6603A, 6603AR, 6603D, and 6603D Operation Manual Download Page 16](http://html1.mh-extra.com/html/topward/6302a-6302ar-6302d-6302dr-6303a-6303ar-6303d-6303dr-6306a-6306ar-6306d-6306dr-6603a-6603ar-6603d-and-6603d/6302a-6302ar-6302d-6302dr-6303a-6303ar-6303d-6303dr-6306a-6306ar-6306d-6306dr-6603a-6603ar-6603d-and-6603d_operation-manual_1129994016.webp)
6000 Series
4. Maintenance
4.1
Changing the Fuse
The fuse is located inside the input power fuse holder (refer to Figure 2). You need to change the fuse when:
•
the fuse is blown out
•
you change the voltage rating
In any case, replace the fuse with one of the same rating. Refer to Table 1 for the type of fuse used for each
model and voltage.
NOTE
:
Unplug the power cord before you change the fuse.
4.2
Changing the Voltage
To change the voltage, follow these steps:
1.
Use a flathead screwdriver to detach the Input Power Fuse Holder and Input Voltage Selector unit
(refer to Figure 2).
2.
Turn the unit so that the desired input voltage is positioned above the
mark.
4.
Check that the fuse to conform to this new voltage rating. Refer to Table 1 below for the correct fuse
rating.
5.
Replace the Input Power Fuse Holder and Input Voltage Selector unit.
Table 1
Power Supply Weight , Dimensions and Fuse Specification
Model
Weight (Approx.)
Dimensions
W x H x D (mm)
Fuse
Time-Delay Type 6 x 30 mm
Net
Gross
Machine
Package
100V
120V
220V
240V
6302A/AR/D/DR
9.0 KG 10.5 KG
230x160x324 364x265x422
4A 4A 2A 2A
6303A/AR/D/DR
9.0 KG 10.5 KG
230x160x324 364x265x422
5A 5A 2.5A
2.5A
6306A/AR/D/DR
13 KG
14.4 KG
230x160x366 364x265x464
8A 8A 4A 4A
6603A/AR/D/DR
13 KG
14.4 KG
230x160x366 364x265x464
8A 8A 4A 4A
13