6000 Series
3.4.3
Parallel Tracking Mode
Under this mode, the - Master Output Terminal is shorted with the - Slave Output Terminal while the +
Master Output Terminal is shorted with the + Slave Output Terminal automatically.
This parallel output is generated from the + Master Output Terminal and the -Master Output Terminal (or -
Slave Output Terminal). The output current is twice the set master current while the output voltage is the
same as the master setting value.
To operate in the parallel mode:
1.
Set the TRACKING MODE switches on the front panel to PAR.
2.
Turn on the POWER switch.
3.
Turn the SLAVE Current and Voltage Adjustment Knobs clockwise to maximum.
4.
Set the master output voltage and current as described in section 3.2.
+
-
V
A
+
-
+
-
5V5A
V1
OVER LOAD
V1
Figure 5 Parallel Connection