TOPVERT G1/H1/P1 Series
E-25
Pr4-03
The 4th step speed of PLC Run or MSS Run
0.00
~
600.00 Hz
(H1:00.0
~
6000.0Hz)
0.00
Pr4-04
The 5th step speed of PLC Run or MSS Run
0.00
~
600.00 Hz
(H1:00.0
~
6000.0Hz)
0.00
Pr4-05
The 6th step speed of PLC Run or MSS Run
0.00
~
600.00 Hz
(H1:00.0
~
6000.0Hz)
0.00
Pr4-06
The 7th step speed of PLC Run or MSS Run
0.00
~
600.00 Hz
(H1:00.0
~
6000.0Hz)
0.00
Pr4-07
The 8th step speed of PLC Run or MSS Run
0.00
~
600.00 Hz
(H1:00.0
~
6000.0Hz)
0.00
Pr4-08
The 9th step speed of PLC Run or MSS Run
0.00
~
600.00 Hz
(H1:00.0
~
6000.0Hz)
0.00
Pr4-09
The 10th step speed of PLC Run or MSS Run
0.00
~
600.00 Hz
(H1:00.0
~
6000.0Hz)
0.00
Pr4-10
The 11th step speed of PLC Run or MSS Run
0.00
~
600.00 Hz
(H1:00.0
~
6000.0Hz)
0.00
Pr4-11
The 12th step speed of PLC Run or MSS Run
0.00
~
600.00 Hz
(H1:00.0
~
6000.0Hz)
0.00
Pr4-12
The 13th step speed of PLC Run or MSS Run
0.00
~
600.00 Hz
(H1:00.0
~
6000.0Hz)
0.00
Pr4-13
The 14th step speed of PLC Run or MSS Run
0.00
~
600.00 Hz
(H1:00.0
~
6000.0Hz)
0.00
Pr4-14
The 15th step speed of PLC Run or MSS Run
0.00
~
600.00 Hz
(H1:00.0
~
6000.0Hz)
0.00
Pr4-15
The duration of master speed
0.0
~
65500 Sec
0.0
Pr4-16
The 1st step duration of PLC Run or MSS Run
0.0
~
65500 Sec
0.0
Pr4-17
The 2nd step duration of PLC Run or MSS Run
0.0
~
65500 Sec
0.0
Pr4-18
The 3rd Step duration of PLC Run or MSS Run
0.0
~
65500 Sec
0.0
Pr4-19
The 4th Step duration of PLC Run or MSS Run
0.0
~
65500 Sec
0.0
Pr4-20
The 5th Step duration of PLC Run or MSS Run
0.0
~
65500 Sec
0.0
Pr4-21
The 6th Step duration of PLC Run or MSS Run
0.0
~
65500 Sec
0.0
Pr4-22
The 7th Step duration of PLC Run or MSS Run
0.0
~
65500 Sec
0.0
Pr4-23
The 8th Step duration of PLC Run or MSS Run
0.0
~
65500 Sec
0.0
Pr4-24
The 9th Step duration of PLC Run or MSS Run
0.0
~
65500 Sec
0.0
Pr4-25
The 10th Step duration of PLC Run or MSS Run 0.0
~
65500 Sec
0.0
Pr4-26
The 11th Step duration of PLC Run or MSS Run 0.0
~
65500 Sec
0.0
Pr4-27
The 12th Step duration of PLC Run or MSS Run 0.0
~
65500 Sec
0.0
Pr4-28
The 13th Step duration of PLC Run or MSS Run 0.0
~
65500 Sec
0.0
Pr4-29
The 14th Step duration of PLC Run or MSS Run 0.0
~
65500 Sec
0.0
Pr4-30
The 15th Step duration of PLC Run or MSS Run 0.0
~
65500 Sec
0.0
Pr4-31
The PLC Run or MSS Run time multiplier
1
~
10
1
Pr4-32
The PLC Run or MSS Run operation direction of
each step
00000~07FFF
(0
:
forward
;
1
:
reverse
)
h00000
Pr4-33
PLC Run operation mode
Bit 0
(bxxxx0)
0
Direction
determined by
Pr4-32
b01000
1
Direction
determined by the
master speed
Bit 1
(bxxx0x)
0
Without zero
intervals
(Continue mode)
1
With zero
intervals (Stop
mode)
Bit 2
(bxx0xx)
0
Run zero speed
when PLC Run
Paused
1
Run original