Cleaning
The walker can be cleaned with normal household detergents. Do not use scrub detergents, steam- or high-pres-
sure cleaners. The walker cannot be hosed because of the electric motor.
Disinfection
Disinfection must only be carried out by authorized personnel and by wearing sufficient protective equipment. The
surface must be cleaned with at disinfection that contains 70–80 % ethanol. We advise against disinfection contain-
ing chlorine and phenol.
The manufacturer cannot be held responsible for any damage or wounds that might occur by
the use of harmful disinfection or disinfection carried out by unauthorized personnel.
Inspection // Maintenance // Re-use
The wheel bearings are sealed and maintenance-free. The other parts do not need to be lubricated. It is recom-
mended that general inspection and maintenance is carried out and that the items below are checked frequently
(how frequent is determined by how and how often the walker is used): Tubes, frame and screws, cables, handles
and forearm supports, brakes, wheels and accessories. This also applies when the walker is to be prepared for re-
use. Please see detailed instructions in this user manual about maintenance of the brakes and cleaning and disin-
fection of the walker.
If the product does not work properly
1
= Possible reason
2
= Action
Brakes
1
Worn out / defect wheel
2
Change the complete wheel
1
Not braking effectively
2
Adjust the brake wire
1
Worn out / defect brake mechanism on wheel
2
Change the entire back wheel section
1
Worn out / defect brake handle
2
Change the complete brake handle
1
Worn out / damaged brake wire
2
Change the brake wire
Height adjustment
1
Battery is flat/does not work
2
Charge or change the battery.
See point 9; charging the battery
1
The height adjustment does not work
2
See point 9; charging the battery
It only goes down, not up
1
The battery is not correctly mounted
2
Check that the battery is clean and correctly mounted
1
Loose cable contact
2 Check that all contacts are properly in place and
tightly
fitted
1
Damage on the cable
2
Check all cables and replace any damaged one(s)
1
Defect switch
2
Change the switch
1
Defect height adjusting panel (accessory)
2
Change the height adjusting panel
In the event that all of the above has been checked and the product is still not operating correctly, then the
cause may be damage to the control box or actuator. Please contact your supplier.
Accessories
For pictures and TOPRO article numbers please see the inside of the cover. Accessories mounted on the walker may
influence stability, we therefore advise you to use them carefully.
A
Height adjustment panel
B
Brake handle left side
C
Adjustable handles
D
Table
E
Stand for body fluid-boxes
F
Small basket
G
Holder for oxygen
H
Footplate
I
Infusion stand
J
Wall mount for battery charger
The accessories are to be ordered separately to give the possibility to compose a TOPRO TAURUS that suits the indi-
vidual users need. Contact your mobility shop, dealer or TOPRO for an updated overview of the accessories, or visit
our homepage
www.topro.co.uk
In case of questions or product faults, please contact your mobility shop or dealer.