5.4- ELECTRIC CONNECTIONS (Wiring diagram)
THE ELECTRIC CONNECTION OF THE ACTUATOR CAN BE PERFORMED ONLY BY
COMPETENT AND QUALIFIED TECHNICAL PERSONNEL SATISFYING THE TECHNICAL
AND PROFESSIONAL REQUIREMENTS FORESEEN BY THE LAW IN FORCE IN THE
COUNTRY OF INSTALLATION ISSUING TO THE CUSTOMER A DECLARATION OF
CONFORMITY FOR THE CONNECTION AND/OR THE PLANT PERFORMED.
BEFORE PERFORMING THE ELECTRIC CONNECTION OF THE ACTUATOR, VERIFY THE
CORRECT INSTALLATION ON THE WINDOW.
THE MAINS TO WHICH THE ACTUATOR IS CONNECTED MUST COMPLY WITH THE
REQUIREMENTS OF THE LAWS IN FORCE IN THE COUNTRY OF INSTALLATION, AS
WELL AS SATISFY THE TECHNICAL FEATURES GIVEN IN TAB.1 AND ON THE RATING
PLATE AND THE "CE" MARKING (PAR.3.1), AS WELL AS BE EQUIPPED WITH A
SUITABLE "EARTHING PLANT".
THE SECTION OF THE MAINS CABLES MUST BE PROPERLY SIZED ACCORDING TO THE
ABSORBED ELECTRIC POWER (SEE RATING PLATE AND "CE" MARKING).
ANY TYPE OF ELECTRIC MATERIAL (PLUG, CABLE, TERMINALS, ETC.) USED FOR THE
CONNECTION MUST BE SUITABLE FOR THE USE, WITH "CE" MARKING AND
COMPLYING WITH THE REQUIREMENTS FORESEEN BY THE LAWS IN FORCE IN THE
COUNTRY OF INSTALLATION.
IT IS COMPULSORY TO INSTALL UPSTREAM OF THE MAINS A SECTIONING DEVICE
WITH A 30 mA DIFFERENTIAL PROTECTION, ASSOCIATED WITH THE EARTHING PLANT.
TO ASSURE A CORRECT SEPARATION FROM THE MAINS, IT IS COMPULSORY TO
INSTALL UPSTREAM OF THE DEVICE A BIPOLAR TEMPORARY SWITCH (PUSH-
BUTTON) OF APPROVED TYPE. UPSTREAM OF THE CONTROL LINE, IT IS
COMPULSORY TO INSTALL AN UNIPOLAR CUTOUT SWITCH WITH CONTACT OPENING
OF AT LEAST 3 mm.
5.5- CONTROL DEVICES
THE CONTROL DEVICES USED TO DRIVE THE ACTUATOR MUST ASSURE THE SAFETY
CONDITIONS FORESEEN BY THE LAWS IN FORCE IN THE COUNTRY OF USE.
IT IS FORBIDDEN TO PERFORM THE CONNECTION TO THE EARTHING PLANT OF THE
ACTUATORS EQUIPPED WITH DOUBLE INSULATION (MOD. ACK42).
BEFORE PERFORMING THE ELECTRIC CONNECTION OF THE ACTUATOR, VERIFY
THAT THE POWER SUPPLY CABLE IS NOT DAMAGED. SHOULD IT BE DAMAGED, IT
MUST BE REPLACED BY THE MANUFACTURER OR BY THE TECHNICAL ASSISTANCE
SERVICE OR IN ANY CASE BY AUTHORIZED OPERATORS.
According to the different type of installations, the actuators can be driven by the
following control devices:
19
C30
INSTALLATION -5
INSTALLATION AND USE ISTRUCTIONS
VER.1.0
REV.07.04