17
Lavac Electric pump Installation
1. Connect up wiring as indicated in the
diagram. The time switch should be
mounted through the bulkhead so that
only the front flange with push button and
shroud are visible to the user. Use only
stainless steel screws.
2. The time switch is set for 30-45 sec-
onds. If you wish to adjust the operating
time (inlet pipe length will vary between
installations), turn the small screw in the
centre of the back of the switch very
slightly in a clockwise direction to length-
en the time and anti-clockwise to reduce
it (time switch is adjustable between
approx 1 second and 10 minutes).
3. Ensure when mounting the pump
that the flow arrows are facing upwards.
Do not mount in a horizontal position.
Also ensure that the pump is no lower
than the top of the bowl.
4. WARNING. Do not operate the
switch while using the toilet. As a precau-
tion, mount the switch in such a position
that children cannot reach it until after
use.
The Electric Lavac can be fitted with
a standby manual pump to provide
emergency back up. It is easy to
upgrade existing hand toilets to elec-
tric or add a standby pump to elec-
tric toilets.
BLACK or BLUE LEAD
RED or BROWN LEAD
TERMINAL BLOCK
ON PUMP MOTOR
12 OR 24 VOLT
BATTERY
(OR DC SUPPLY)
5 AMP FUSE
+ HOLDER
MINIMUM WIRE SIZE 30/.25 (30 STRANDS/0.25mm)
PUSH-BUTTON
TIME SWITCH
(Loom)
{
Black/Blue - Black/Blue
}
(Pump)
Red/Brown - Red/Brown
Summary of Contents for BLAKES LAVAC Popular 4610-000
Page 6: ...6 Exploded diagram of the Lavac Popular...
Page 10: ...10 Exploded diagram of the electric pump 12 24 Volt...
Page 13: ...13 Lavac operation...