14
TOPEX.PL
3. Measurement over-range indication: display of digit „ „.
4. Measurement rate: 2-3 updates per second.
5. Operating temperature: 0ºC – 40ºC, relative humidity < 75%.
6. Storage temperature: -10ºC – 45ºC, relative humidity < 75 %
7. Power supply: 9V battery (6F22).
8. Empty battery indicator:
on the LCD display.
9. Size: 138 x 70 x 28 mm.
10. Weight: 115g (with battery).
FUNCTIONS, RANGE, ACCURACY
Accuracy is given for the period of 1 year since the first calibration at operating temperature
18ºC – 26ºC and maximum relative humidity 75%.
Accuracy is given as +- [(% of value read) + (number of least significant digits)].
FUNCTION: DIRECT VOLTAGE MEASUREMENT
RANGE
RESOLUTION
ACCURACY
200mV
100μV
+- (0,5% + 2)
2000mV
1mV
+- (0,8% + 2)
20V
10mV
+- (0,8% + 2)
200V
100mV
+- (0,8% + 2)
600V
1V
+- (1,0% + 2)
FUNCTION: ALTERNATING VOLTAGE MEASUREMENT
RANGE
RESOLUTION
ACCURACY
200V
100mV
+- (1,2% + 10)
600V
1V
+- (1,2% + 10)
Measurement of RMS value of sinusoidal function from frequency range 45Hz to 450Hz.
FUNCTION: DIRECT CURRENT MEASUREMENT
RANGE
RESOLUTION
ACCURACY
2000μA
1μA
+- (1,0% + 2)
20mA
10μA
+- (1,0% + 2)
200mA
100μA
+- (1,2% + 2)
10A
10mA
+- (2,0% + 2)
Overload protection of measurement ranges up to 200mA: quick blow fuse 250mA/250V. 10A
range has no overload protection.
Summary of Contents for 94W101
Page 18: ...18 TOPEX PL 94W101 94W101 IEC 1010 II CAT II 600 II 200 AC DC II RU...
Page 19: ...19 TOPEX PL 1 2 3 4 100 5 6 7 8 9 10 11 12 13 14 40 20 rms...
Page 20: ...20 TOPEX PL 15 16 17 600 10A 18 II III IV 19 1 2 3 5 4 1 3 1999 2 OFF OFF...
Page 23: ...23 TOPEX PL 3 1 VmA COM 2 3 1 VmA COM 200 10A 10A 10 15 10A 2 3 4 1 VmA COM 2...
Page 24: ...24 TOPEX PL 3 4 1 VmA COM 2 3 4 5 6 1 VmA COM 2 1 5 9 3 1 2 OFF 3 2 4 6F22 1 OFF 2 2 F250 250...
Page 25: ...25 TOPEX PL...
Page 26: ...26 TOPEX PL 94W101 94W101 IEC 1010 II CAT II 600V II 200 AC DC II UA...
Page 27: ...27 TOPEX PL 1 2 3 4 5 6 7 8 9 10 11...
Page 28: ...28 TOPEX PL 12 13 14 40 20 rms 15 16 17 600 10A 18 II III IV 19 1 2 3 5 4...
Page 32: ...32 TOPEX PL 2 3 4 1 VmA COM 2 3 4 1 VmA COM 2 3 4 5 6 1 VmA COM 2 1 5 9...
Page 33: ...33 TOPEX PL 3 1 2 OFF 3 2 4 6F22 1 OFF 2 2 F250 250...
Page 71: ...71 TOPEX PL...