15
DIP Switch #3
–
#5: Fine adjust the soft stop period of the motor
DIP Switch #3: ON
–
1 Second
OFF
–
0
DIP Switch #4: ON
–
2 Seconds
OFF
–
0
DIP Switch #5: ON
–
3 Seconds
OFF
–
0
NOTE: Every time you restart the gate opener after power off, you should use the access control
device (such as remote, push button and etc.) to operate the gate opener to run for a complete
opening cycle and a complete closing cycle to get the full opening time and the full closing time. You
would achieve the soft stop in your next opening/closing cycle. Factory default soft stop time is 3
Second. You can turn the DIP switches on/off to fine adjust the soft stop time to meet your actual
needs.
DIP Switch #6
–
#7: Auto close time of the gate opener
DIP Switch #6: ON
–
30 Seconds
OFF
–
0
DIP Switch #7: ON
–
60 Seconds
OFF
–
0
NOTE: The auto close function would be disabled if both DIP switches are turned to off (factory
default setting).
Important Note: When the auto close function is enabled, the photocell sensor is highly
recommended to be installed with the gate opener for safety.
DIP Switch #8: Left/Right open
2. Potentiometers
Potentiometer A
is used to adjust the close stall force the gate operator. Turn clockwise to increase the stall
force, and turn it counter-clockwise to decrease the stall force.
Potentiometer B
is used to adjust the open stall force the gate operator. Turn clockwise to increase the stall
force, and turn it counter-clockwise to decrease the stall force.
WARNING: Photocell is highly recommended to be installed with the gate opener as entrapment
protection for safety when you set stall force to maximum.
E.g. The soft stop period of the motor is 1+2=3 seconds.
E.g. Auto close time of the gate opener is 30+60=90 seconds.