4-7
4 DISTANCE MEASUREMENT
The horizontal distance from the instrument to the
prism will be measured.
After measuring, the result added offset value will
be shown.
5
Collimate point A
0
using the horizontal motion
clamp and horizontal tangent screw.
Collimate
A
0
6
Show the relative elevation of point A
0
.
[
]
7
Show the slope distance of point A
0
.
z
Each time pressing the [
] key, horizontal
distance, relative elevation and slope distance are
shown in sequence.
[
]
8
Show N coordinate of point A
0
or A
1
.
z
Each time pressing [
] key, N,E and Z
coordinate are shown in sequence.
[
]
z
To return to procedure
4
, press [F1](NEXT) key.
z
To return to the previous mode, press [ESC] key.
OFFSET-MEASUREMENT
HR: 110°20'30"
HD* 56.789 m
>Measuring...
OFFSET-MEASUREMENT
HR: 110°20'30"
HD: 56.789 m
NEXT --- --- ---
OFFSET-MEASUREMENT
HR: 113°30'50"
HD: 56.789 m
NEXT --- --- ---
OFFSET-MEASUREMENT
HR: 113°20'30"
VD: 3.456 m
NEXT --- --- ---
OFFSET-MEASUREMENT
HR: 113°20'30"
SD: 56.894 m
NEXT --- --- ---
OFFSET-MEASUREMENT
HR: 113°20'30"
N : -12.345 m
NEXT --- --- ---
Summary of Contents for GTS-230N
Page 2: ......
Page 144: ...12 4 12 SETTING ATMOSPHERIC CORRECTION...
Page 145: ...12 5 12 SETTING ATMOSPHERIC CORRECTION...
Page 182: ...EMC NOTICE Utilizing recycled paper 2008 TOPCON CORPORATION ALL RIGHTS RESERVED...
Page 183: ......