16-1
16 SELECTING MODE
16
SELECTING MODE
16.1 Items of the Selecting Mode
The following modes are available.
Menu
Items
Selecting item
Display
1:
UNIT SET
TEMP. &
PRES.
°C/°F
hPa/mmHg/inHg
Select the unit of temperature for atmospheric
correction. Select the unit of air pressure for
atmospheric correction.
ANGLE
DEG (360°)/
GON (400G)/
MIL (6400M)
Choose degree, gon or mil unit for measuring
angle.
DISTANCE
METER/FEET/
FEET and inch
Choose measuring unit for distance meter, feet or
feet and inch
FEET
US SURVEY/
INTERNATIONAL
Select the meter/feet conversion factor.
US SURVEY feet
1m=3.280833333333333 ft.
INTERNATIONAL feet
1m=3.280839895013123 ft.
2:
MODE SET
POWER ON
MODE
ANGLE MEAS./
DISTANCE MEAS.
Select to set the measurement mode for angle or
distance when the power is turned on.
FINE/CRS/
TRK
FINE/COARSE/
TRACK
Select Fine/Coarse/Tracking mode in distance
measurement mode, when the power is turned on.
HD&VD/SD
HD&VD/SD
Specify which is displayed first, horizontal and
vertical distance or slope distance, when the power
is turned on.
V ANGLE Z0/
H0
Zenith 0/
Horizontal 0
Choose the vertical angle reading from zenith or
from level.
N-TIMES/
REPEAT
N-TIMES/
REPEAT
Select the measurement mode for distance when
the power is turned on.
TIMES OF
MEAS.
0~99
Set N (number of times) for times of distance
measurement. When setting number of times as 1,
it is single measurement.
NEZ/ENZ
NEZ/ENZ
Select a coordinate displaying order either NEZ or
ENZ.
HA MEMORY
ON/OFF
Horizontal angle set can be retained after the power
is turned off.
ESC KEY
MODE
DATA COLLECT/
LAYOUT/REC/
OFF
You can select a function of the [ESC] key.
DATA COLLECT/LAYOUT: It is possible to enter
data input mode (in DATA COLLECT) or Layout
Menu from normal measuring mode directly.
REC: While executing normal or offset measuring,
the measuring data can be output.
OFF: Returns to normal function.
COORD.
CHECK
ON/OFF
Select coordinate displaying ON or OFF when
setting a point.