background image

 

D4008 – EN                                        EZ 2810 Operators Manual 

31 

SETTING 

[display] 

D.A.N 

NO. 

OPTIONS [displayed] 

BOLD=DEFAULT 

DESCRIPTION 

MENU 2  -  COMMUNICATIONS FEATURES 

REMOTE 

2001 

ON/

OFF

 

If ON indicator communicates with Cab Control Display 

SCALE NUMBER  2002 

1

,2,3,4,5,6,7,8,9,10,11,12, 

13,14,15,16,17,18,19,20, 
21,22,23,24 

Select scale number for cab control communication 

EXTERNAL 
RADIO 

2003 

ON/

OFF

 

Enables external radio to be connected to the J905 port. 

DDL ATTACHED 

2004 

YES/

NO

 

Enables connection of a DDL (Data DownLoader) 

SCOREBOARD 
MODE 

2101 

0

,1,2,3,4,5,6,7,8,11,12,15,

27,37,38,39 

Select scoreboard output 

ZERO OUTPUT 

2102 

 

Allows zero/balance for SCOREM #11 serial gross weight. 

FRONT PANEL 
ZEROUT 

2103 

OFF/

ON

  

 

Allows use of the zero key to zero/balance the serial gross weight. 

OPERATION 
STATUS 

2111 

0

, 2 

Select operating data to be sent to a Remote Terminal 

COM 1 BAUD 
RATE 

2201 

1200,2400, 4800, 

9600

14400, 19200, 38400, 
57600, 115200 

Sets baud rate for com port #1 

COM 1 PARITY 

2202 

NONE, ODD,

 EVEN 

Sets parity for com port #1 
 

COM 1 DATA 
BITS 

2203 

7

, 8 

Sets data bits for com port #1 
 

COM 1 DELAY 

2204 

0, 

.10

, .25, .50, .75, 1-5 

Selects seconds to delay before advancing to next line. 

COM 2 BAUD 
RATE 

2211 

1200,2400, 4800, 

9600

14400, 19200, 38400, 
57600, 115200 

Sets baud rate for com port #2 

COM 2 PARITY 

2212 

NONE

, ODD, EVEN 

Sets parity for com port #2 

COM 2 DATA 
BITS 

2213 

7, 

8

 

Sets data bits for com port #2 

COM 2 DELAY 

2214 

0, 

.10

, .25, .50, .75, 1-5 

Selects seconds to delay before advancing to next line. 

TARE AUTO 
PRINT  

2301 

ON/

OFF

 

If ON -tare auto-prints displayed weight. 

ONE LINE PRINT  

2302 

ON/

OFF

 

If ON -indicator data prints on one line. 
 

AUTO PRINT 

2303 

ON/

OFF

 

If ON -pressing keys auto-prints weight values. 

Summary of Contents for EZ2810

Page 1: ...D4008 EN Rev F January 13 2020 EZ2810 With Bluetooth EZ2810 Operators Manual...

Page 2: ...icas W5527 Hwy 106 Fort Atkinson WI 53538 USA Tel 800 225 7695 E mail sales digi star com Topcon Agriculture International Topcon Agriculture Europe B V J F Kennedylaan 235 NL 5981 WZ Panningen The Ne...

Page 3: ...t for use with applications for which the EZ2810 is not intended or as outlined in this manual Use of the EZ2810 outside of its intended purposes may result in inaccurate weight measurement or damage...

Page 4: ...20 SECTION 2 ADVANCE COMMANDS 21 2 1 0 Hold Mode 21 2 2 0 Preset 21 2 3 0 Clear Preset 21 2 4 0 Preset Load 22 2 5 0 Load Unload Mode 22 2 6 0 Net Mode 22 2 7 0 Preload a Tare 23 2 8 0 Pre Alarm 23 2...

Page 5: ...Data Transfer Options 39 7 6 0 Rotation Counter Sensor 39 SECTION 8 TROUBLESHOOTING 40 8 1 0 Flow Chart 40 8 2 0 Flow Chart 41 SECTION 9 DECLARATION OF CONFORMITY CERTIFICATES 42 9 1 0 xx10 Series Ind...

Page 6: ...ul benefit of monitoring mix revolutions or mix time and a warning light buzzer or external signal will indicate when the desired mix revolutions or time has been achieved For this the EZ2810 uses an...

Page 7: ...ls are installed correctly Incorrect installation of load cells will result in inaccurate measurement Load cells should not be subjected to any strains or loads other than the weight of the load Stres...

Page 8: ...10 5V nominal POUND KILOGRAM Selectable DISPLAY 6 Digit Chip on Glass LCD 1 7 high DISPLAY RESOLUTION 01 02 05 1 2 5 1 2 5 10 20 50 100 DISPLAY UPDATE RATE Selectable 1 2 3 4 times sec MAX DISPLAY RES...

Page 9: ...ion Read and understand this manual and learn all controls before you use the equipment Check that the area is clear of people animals and obstacles before starting any work Identify possible hazards...

Page 10: ...es from the scale indicator as noted in diagram below before charging the battery or welding on the machine If cables are left connected the scale indicator optional devices and connected load cells c...

Page 11: ...on Pressing while on will run self test Turns indicator off Display Window Displays current actions Temporary zero Net mode Records to memory or prints displayed weight Toggles between Net and Gross w...

Page 12: ...ional information for last key pressed Serial Printer Port Option port for connection with other devices Remote Port Optional remote display Load Cell Port For J Box cord Power Port For power cord Ser...

Page 13: ...re and Net Gross 1 Press 1 1 Press and hold for 3 seconds to zero balance indicator 1 Flashing arrow points to gross next to the display window indicator ready to weigh 2 Weight displayed press sets z...

Page 14: ...ight and flashing arrow on side of display points to NET 4 5 6 7 5 Add more weight 6 To know total of original weight of 4000 pounds plus added 300 pounds press to show 4300 pounds flashing arrow poin...

Page 15: ...time 1 7 0 Restart Mix Timer 1 Press Indicator sends data to printer or PC 8 22 14 3 08P ID 4300LB GR LB PR Date in ddmmyy Time Weight Gross GR or Net NET 1 1 Press 2 Enter time press Time runs down...

Page 16: ...ding weigh to weight memory RM Recall weight memory CM Clear weight memory MS Stores display weight to memory Dimmer Dimming backlight Menu View menus 1 2 3 4 and calibrate See page 29 Setup Change se...

Page 17: ...weighing mode 4 Put another weight on the scale Example 1000 pounds 4 5 8 6 7 5 Press will briefly be displayed followed by This will add another 1000 lbs to indicator memory and return to gross weigh...

Page 18: ...st have optional serial printer port for printing 1 9 2 Weight Averaging 1 Repeatedly press until displayed 2 Press shows weight in memory Example 1500 pounds 3 Press while weight displayed Sample Out...

Page 19: ...weight average 3 Display shows if number of individual weights to average is two Example weight of 1000 pounds and 500 pounds averaged 4 Displays AVERAG 5 Display shows average of two weights in memor...

Page 20: ...Store Stores display weight 1 9 5 Clear Memory 1 Press while average weight is displayed Sample output format Counts Average Weight 8 22 14 3 08P 2CT 1500LB AV LB PR Date Time 1 1 Repeatedly press un...

Page 21: ...2 3 0 Clear Preset 1 Press holds displayed weight indicator flashes weight and HOLD Press returns indicator back to normal 2 If weight added while in hold mode press cancels hold 1 Enter desired pres...

Page 22: ...alue alternates between flashing word PRESET and amount until 5 percent of weight is loaded or unloaded 1 Press Displays amount remaining to load or unload As ingredients are loaded or unloaded displa...

Page 23: ...Preset Pre alarm activates the alarm buzzer and light at a weight or percentage of preset value Enter 1103 then press to access Pre Tare Press to enable the option Press to return to weighing mode 1...

Page 24: ...2 Repeatedly press displays tolerance amount by percentage 3 Press stores setting 4 Enter number for tolerance setting 5 Press stores setting NOTE OFF Setting always advances after ingredient amount r...

Page 25: ...art Rotation Counter 2 9 4 Setting Drive Ratio Drive ratio is number of turns seen by sensor divided by number of mixing rotations 1 Press twice 2X starts rotation counter using previous count 1 1 Ent...

Page 26: ...operator s manual 1 Enter 8011 press The user may edit the maintenance message using keypad 1 2 MANTMG 1 then edit maintenance message using key pad Key pad 1 does Example 1 A B C Key pad 2 does Exam...

Page 27: ...operation time then maintenance message will be displayed on LCD User will need to acknowledge message by pressing ON key Message will be displayed on each power cycle and every 4 hours of operation...

Page 28: ...Calibration Number 1 Enter 8711 press 2 Indicator shows SETUP briefly then shows a 6 digit number on LCD This is the current Setup Number Enter new number if required 3 Press 2 1 3 1 Enter 8712 press...

Page 29: ...uese Spanish Danish Hungarian Spanish Polish Select language to be displayed DISPLAY RATE 1002 1 2 3 4 6 7 8 9 10 Update display times per second SCALE ID SETUP 1003 NEW EZ Identity of scale location...

Page 30: ...Z Message that is displayed for remote input condition D A N 1401 set to switch REMOTE 1 SWITCH STATE 1403 OPEN CLOSED Set remote input line state that displays message and or illuminates alarm lamp...

Page 31: ...the serial gross weight OPERATION STATUS 2111 0 2 Select operating data to be sent to a Remote Terminal COM 1 BAUD RATE 2201 1200 2400 4800 9600 14400 19200 38400 57600 115200 Sets baud rate for com...

Page 32: ...TIMER GRAPH 2415 ON OFF Enables graph to be used with timers when used with an RD4000 Remote Display MENU 3 MOTION WEIGHT DISPLAY COUNT 3001 01 02 05 1 2 5 1 2 5 1 0 20 50 100 Select display count siz...

Page 33: ...will activate 12VDC Alarm Output on Power cord SET POINT COUNT 4105 0 thru 9 Counts how many times set point is activated SET POINT WEIGHT SOURCE 4106 SERIAL NORMAL Sets weight source for use with se...

Page 34: ...Enables editing of the sign on message MAINTENANCE MESSAGE 8011 MANTMG 1 2 3 4 5 6 7 8 9 10 11 Enables editing of the maintenance message MAINTENANCE MESS TIME 8012 Time is entered using key pad Time...

Page 35: ...be securely mounted to the equipment Loose or unsupported Indicators can be damaged STD UNIVERSAL WING MOUNT WEDGE MOUNT MOUNT TALL KEY PART NUMBER DESCRIPTION A 404353 BRACKET EZ3 PLASTIC RAIL B 4037...

Page 36: ...in a Low Voltage warning on the display or the Indicator will power off Voltage spike above 16 volts will damage the Indicator Never weld or charge the battery on the equipment that the Indicator is...

Page 37: ...Cable Connections Scale Remote Indicator Optional See J Box Connections Power Cord Pin To 12VDC Power Supply 1 Red Terminal 2 Black Terminal 3 Orange Alarm Out 4 Blue Remote Input Digital Input output...

Page 38: ...tion Observe direction of arrow when installing or replacing load cells Junction Box Illustrated for 4 Load Cell Installation Tighten Nuts Load Cell Cable Junction Box Cable Connect to J902 Load Cell...

Page 39: ...nsmitter Receiver Single function transmitter for simple one button Tare or Advance operation from the loader cab 7 4 0 Printer Option Use with indicator that has optional serial port installed When a...

Page 40: ...ed to negative side When using a multimeter to check for voltage measure between pin 1 pos and pin 2 neg Meter should read between 10 5 and 14 5 volts DC if using a tractor power cord black wire is po...

Page 41: ...of each Load Cell and how much weight is over each Load Cell In general the number should be positive and stable 5 Stand or hang your weight over the connected Load Cell Record how much the weight in...

Page 42: ...D4008 EN EZ 2810 Operators Manual 42 SECTION 9 Declaration of Conformity Certificates 9 1 0 xx10 Series Indicator without Bluetooth...

Page 43: ...D4008 EN EZ 2810 Operators Manual 43 9 2 0 xx10 Series Indicator with Bluetooth Radio...

Page 44: ...D4008 EN EZ 2810 Operators Manual 44 10 0 0 NOTES...

Reviews: