background image

 

D4008 – EN                                        EZ 2810 Operators Manual 

0.4.0 Technical Specifications 

 

SIZE 

10.25” long x 8.0” high x 4” wide (260mm x 190mm x 105mm) 

WEIGHT  

 4.5 lbs. (2.04 Kg) 

HELP MESSAGES 

Context sensitive help messages in 10 languages, Long messages are 
scrolled 

LOAD CELL EXCITATION 

8 volts D.C. Nominal, Capable of driving ten 350 Ohms transducers, Short 
circuit proof 

AUTO TEMPERATURE 
COMPENSATION 

Of internal circuitry for high accuracy weighing measurements 

LOAD CELL SIGNAL 

Compatible with Load Cells with greater than 0.25 mv/v 

CONNECTORS 

AMP plastic weather resistant circular connector. Gold plated contacts. 

POWER REQUIREMENTS 

10.5 to 16.0 V.D.C.  160 mA nominal with four 350Ω L.C.  

SET UP AND 
CALIBRATION 

Via front panel or USB (???) 

GROSS RANGE 

999,999 max. display 

LOW BATTERY 
WARNING 

Enabled at 10.5V nominal 

POUND/KILOGRAM 

Selectable  

DISPLAY 

6 Digit Chip on Glass LCD 1.7” high 

DISPLAY RESOLUTION 

.01, .02, .05, .1, .2, .5, 1, 2, 5, 10, 20, 50, 100 

DISPLAY UPDATE RATE 

Selectable: 1, 2, 3, 4 times/sec. 

MAX. DISPLAY 
RESOLUTION 

Adjustable to 40,000 counts max.  

ZERO TRACKING 

Selectable, On/Off 

SPAN ACCURACY 

± (.1% + .005%/ °F) or (.1% + 0.009% °C) full scale ± 1 output count 

MOTION DETECTION 

Selectable, On/Off 

ZERO ACCURACY 

(.005%/ °F) or (0.009% °C) full scale ±1 output count for 0.5 mv/v 
transducer 

ENVIRONMENTAL 
ENCLOSURE 

IP65, IEC 529 

WEIGH ALGORITHM  

3 internally selectable digital filters to optimize performance (General, 
Slow, and Fast) 

HOLD MODE  

Used in mobile applications to stabilize displayed weight while moving the 
scale 

NON-VOLATILE 
MEMORY 

Standard 

OPERATING TEMP   

 -29°C to 60°C       -20°F to 140°F     

2 REMOTE INPUTS 
(Power/Remote ports) 

Tare / Print / Hold / Net Gross / M+ / Zero / TR Hold / Re-enter Preset / 
Switch 

REMOTE PORT  
Power Output 

2 x Large Display LED Remote Displays (RD4000) or 3 x Standard 
Display Remote Displays (RD2500V) 

 

 

Summary of Contents for EZ2810

Page 1: ...D4008 EN Rev F January 13 2020 EZ2810 With Bluetooth EZ2810 Operators Manual...

Page 2: ...icas W5527 Hwy 106 Fort Atkinson WI 53538 USA Tel 800 225 7695 E mail sales digi star com Topcon Agriculture International Topcon Agriculture Europe B V J F Kennedylaan 235 NL 5981 WZ Panningen The Ne...

Page 3: ...t for use with applications for which the EZ2810 is not intended or as outlined in this manual Use of the EZ2810 outside of its intended purposes may result in inaccurate weight measurement or damage...

Page 4: ...20 SECTION 2 ADVANCE COMMANDS 21 2 1 0 Hold Mode 21 2 2 0 Preset 21 2 3 0 Clear Preset 21 2 4 0 Preset Load 22 2 5 0 Load Unload Mode 22 2 6 0 Net Mode 22 2 7 0 Preload a Tare 23 2 8 0 Pre Alarm 23 2...

Page 5: ...Data Transfer Options 39 7 6 0 Rotation Counter Sensor 39 SECTION 8 TROUBLESHOOTING 40 8 1 0 Flow Chart 40 8 2 0 Flow Chart 41 SECTION 9 DECLARATION OF CONFORMITY CERTIFICATES 42 9 1 0 xx10 Series Ind...

Page 6: ...ul benefit of monitoring mix revolutions or mix time and a warning light buzzer or external signal will indicate when the desired mix revolutions or time has been achieved For this the EZ2810 uses an...

Page 7: ...ls are installed correctly Incorrect installation of load cells will result in inaccurate measurement Load cells should not be subjected to any strains or loads other than the weight of the load Stres...

Page 8: ...10 5V nominal POUND KILOGRAM Selectable DISPLAY 6 Digit Chip on Glass LCD 1 7 high DISPLAY RESOLUTION 01 02 05 1 2 5 1 2 5 10 20 50 100 DISPLAY UPDATE RATE Selectable 1 2 3 4 times sec MAX DISPLAY RES...

Page 9: ...ion Read and understand this manual and learn all controls before you use the equipment Check that the area is clear of people animals and obstacles before starting any work Identify possible hazards...

Page 10: ...es from the scale indicator as noted in diagram below before charging the battery or welding on the machine If cables are left connected the scale indicator optional devices and connected load cells c...

Page 11: ...on Pressing while on will run self test Turns indicator off Display Window Displays current actions Temporary zero Net mode Records to memory or prints displayed weight Toggles between Net and Gross w...

Page 12: ...ional information for last key pressed Serial Printer Port Option port for connection with other devices Remote Port Optional remote display Load Cell Port For J Box cord Power Port For power cord Ser...

Page 13: ...re and Net Gross 1 Press 1 1 Press and hold for 3 seconds to zero balance indicator 1 Flashing arrow points to gross next to the display window indicator ready to weigh 2 Weight displayed press sets z...

Page 14: ...ight and flashing arrow on side of display points to NET 4 5 6 7 5 Add more weight 6 To know total of original weight of 4000 pounds plus added 300 pounds press to show 4300 pounds flashing arrow poin...

Page 15: ...time 1 7 0 Restart Mix Timer 1 Press Indicator sends data to printer or PC 8 22 14 3 08P ID 4300LB GR LB PR Date in ddmmyy Time Weight Gross GR or Net NET 1 1 Press 2 Enter time press Time runs down...

Page 16: ...ding weigh to weight memory RM Recall weight memory CM Clear weight memory MS Stores display weight to memory Dimmer Dimming backlight Menu View menus 1 2 3 4 and calibrate See page 29 Setup Change se...

Page 17: ...weighing mode 4 Put another weight on the scale Example 1000 pounds 4 5 8 6 7 5 Press will briefly be displayed followed by This will add another 1000 lbs to indicator memory and return to gross weigh...

Page 18: ...st have optional serial printer port for printing 1 9 2 Weight Averaging 1 Repeatedly press until displayed 2 Press shows weight in memory Example 1500 pounds 3 Press while weight displayed Sample Out...

Page 19: ...weight average 3 Display shows if number of individual weights to average is two Example weight of 1000 pounds and 500 pounds averaged 4 Displays AVERAG 5 Display shows average of two weights in memor...

Page 20: ...Store Stores display weight 1 9 5 Clear Memory 1 Press while average weight is displayed Sample output format Counts Average Weight 8 22 14 3 08P 2CT 1500LB AV LB PR Date Time 1 1 Repeatedly press un...

Page 21: ...2 3 0 Clear Preset 1 Press holds displayed weight indicator flashes weight and HOLD Press returns indicator back to normal 2 If weight added while in hold mode press cancels hold 1 Enter desired pres...

Page 22: ...alue alternates between flashing word PRESET and amount until 5 percent of weight is loaded or unloaded 1 Press Displays amount remaining to load or unload As ingredients are loaded or unloaded displa...

Page 23: ...Preset Pre alarm activates the alarm buzzer and light at a weight or percentage of preset value Enter 1103 then press to access Pre Tare Press to enable the option Press to return to weighing mode 1...

Page 24: ...2 Repeatedly press displays tolerance amount by percentage 3 Press stores setting 4 Enter number for tolerance setting 5 Press stores setting NOTE OFF Setting always advances after ingredient amount r...

Page 25: ...art Rotation Counter 2 9 4 Setting Drive Ratio Drive ratio is number of turns seen by sensor divided by number of mixing rotations 1 Press twice 2X starts rotation counter using previous count 1 1 Ent...

Page 26: ...operator s manual 1 Enter 8011 press The user may edit the maintenance message using keypad 1 2 MANTMG 1 then edit maintenance message using key pad Key pad 1 does Example 1 A B C Key pad 2 does Exam...

Page 27: ...operation time then maintenance message will be displayed on LCD User will need to acknowledge message by pressing ON key Message will be displayed on each power cycle and every 4 hours of operation...

Page 28: ...Calibration Number 1 Enter 8711 press 2 Indicator shows SETUP briefly then shows a 6 digit number on LCD This is the current Setup Number Enter new number if required 3 Press 2 1 3 1 Enter 8712 press...

Page 29: ...uese Spanish Danish Hungarian Spanish Polish Select language to be displayed DISPLAY RATE 1002 1 2 3 4 6 7 8 9 10 Update display times per second SCALE ID SETUP 1003 NEW EZ Identity of scale location...

Page 30: ...Z Message that is displayed for remote input condition D A N 1401 set to switch REMOTE 1 SWITCH STATE 1403 OPEN CLOSED Set remote input line state that displays message and or illuminates alarm lamp...

Page 31: ...the serial gross weight OPERATION STATUS 2111 0 2 Select operating data to be sent to a Remote Terminal COM 1 BAUD RATE 2201 1200 2400 4800 9600 14400 19200 38400 57600 115200 Sets baud rate for com...

Page 32: ...TIMER GRAPH 2415 ON OFF Enables graph to be used with timers when used with an RD4000 Remote Display MENU 3 MOTION WEIGHT DISPLAY COUNT 3001 01 02 05 1 2 5 1 2 5 1 0 20 50 100 Select display count siz...

Page 33: ...will activate 12VDC Alarm Output on Power cord SET POINT COUNT 4105 0 thru 9 Counts how many times set point is activated SET POINT WEIGHT SOURCE 4106 SERIAL NORMAL Sets weight source for use with se...

Page 34: ...Enables editing of the sign on message MAINTENANCE MESSAGE 8011 MANTMG 1 2 3 4 5 6 7 8 9 10 11 Enables editing of the maintenance message MAINTENANCE MESS TIME 8012 Time is entered using key pad Time...

Page 35: ...be securely mounted to the equipment Loose or unsupported Indicators can be damaged STD UNIVERSAL WING MOUNT WEDGE MOUNT MOUNT TALL KEY PART NUMBER DESCRIPTION A 404353 BRACKET EZ3 PLASTIC RAIL B 4037...

Page 36: ...in a Low Voltage warning on the display or the Indicator will power off Voltage spike above 16 volts will damage the Indicator Never weld or charge the battery on the equipment that the Indicator is...

Page 37: ...Cable Connections Scale Remote Indicator Optional See J Box Connections Power Cord Pin To 12VDC Power Supply 1 Red Terminal 2 Black Terminal 3 Orange Alarm Out 4 Blue Remote Input Digital Input output...

Page 38: ...tion Observe direction of arrow when installing or replacing load cells Junction Box Illustrated for 4 Load Cell Installation Tighten Nuts Load Cell Cable Junction Box Cable Connect to J902 Load Cell...

Page 39: ...nsmitter Receiver Single function transmitter for simple one button Tare or Advance operation from the loader cab 7 4 0 Printer Option Use with indicator that has optional serial port installed When a...

Page 40: ...ed to negative side When using a multimeter to check for voltage measure between pin 1 pos and pin 2 neg Meter should read between 10 5 and 14 5 volts DC if using a tractor power cord black wire is po...

Page 41: ...of each Load Cell and how much weight is over each Load Cell In general the number should be positive and stable 5 Stand or hang your weight over the connected Load Cell Record how much the weight in...

Page 42: ...D4008 EN EZ 2810 Operators Manual 42 SECTION 9 Declaration of Conformity Certificates 9 1 0 xx10 Series Indicator without Bluetooth...

Page 43: ...D4008 EN EZ 2810 Operators Manual 43 9 2 0 xx10 Series Indicator with Bluetooth Radio...

Page 44: ...D4008 EN EZ 2810 Operators Manual 44 10 0 0 NOTES...

Reviews: