125
19. CHANGING THE SETTINGS
It is possible to allocate the softkeys in Observation mode to suit the measurement conditions. It is
possible to operate the instrument efficiently because unique softkey allocations can be preset to suit
various applications and the ways that different operators handle the instrument.
• The current softkey allocations are retained until they are revised again, even when the instrument
is powered OFF.
• Press
[CLEAR]
in <Customize/Select screen> to return all customized configurations including tab
pages, status bar/starkey mode settings, and screen controls to their previous settings.
G
• When softkey allocations are recorded and registered, the previously recorded key settings are
cleared.
• Softkeys cannot be allocated to "Graphic" tabs.
I
Screens that can be customized and softkey allocations when shipped
1. "SHV" and "SHVdist" tabs of <Basic observation>
Page 1
[SRCH] [MOTOR] [0SET] [MEAS]
Page 2
[MENU] [EDM] [H-SET] [COORD]
Page 3
[OFFSET] [RESEC] [REM] [S-O]
2. "Obs." tab of <Setting out>
Page 1
[ --- ] [SHVR] [H.TURN] [MEAS]
Page 2
[CNFG] [ --- ] [ --- ][REM]
Page 3
[ --- ] [ --- ] [ --- ] [ --- ]
3. "SHV" and "NEZ" tabs of <Set out Coords>
Page 1
[OK] [CNFG][H.TURN] [MEAS]
Page 2
[ --- ] [ --- ] [ --- ] [ --- ]
Page 3
[ --- ] [ --- ] [ --- ] [ --- ]
I
Functions that can be allocated to the softkeys
[ --- ]
: No functions set
[MEAS]
: Distance and angle measurement
[0SET]
: Set horizontal angle to 0°
[H-SET]
: Set required horizontal angle
[SHV]
: Switch the "SHV" tab and "SHVdist" tab (can only be allocated to 1
above)
[R/L]
: Select horizontal angle right/left. The capitalized letter in the softkey
indicates the currently selected mode.
[ZA / %]
: Switch between zenith angle/slope in %. The capitalized letter in the
softkey indicates the currently selected mode.
[HOLD]
: Hold horizontal angle/release horizontal angle
[CALL]
: Display final measurement data
[HVOUT-S]
: Output angle measurement results to an external device (SET format)
19.6
Allocating Key Functions
Summary of Contents for DS-101AC
Page 175: ......