TopCold BC145V Instruction Manual Download Page 5

After selecting the parameter item, press Set key to enter current menu item parameter value setting, 

press   

▲or▼ to adjust parameter value, and press Set key again to return to menu interface. 

Under  the  status  of  parameter  setting,  press 

  key  or  no  key  operation  within  30s,  it  will  exit  from 

parameter setting and automatically save the current parameter value. 

Note: Administrator password input only valid once, after pressing 

  key to exit from parameter setting, 

you need to input the password again for next adjustment. 

5.2.2 Temperature viewing 

When parameter U1=00, it displays current cabinet temperature. 

When parameter U1=01, it displays current evaporator temperature. 

In the status of temperature measuring and controlling, press 

  to view the current evaporator sensor 

measured temperature value (evaporator sensor is enabled and keeps normal). 

5.2.3 Manually forced operation 

In the status of temperature measuring and controlling, Press 

  for three seconds to force the open or 

close of defrost.   

    When U3=01, that is, K2 relay works as lighting output, press 

▲ key to open/close lighting. 

5.2.4 Parameter recovery 

In the status of temperature measuring and controlling

press the key 

▼ for 10S

it displays the code HO 

and  enter  to  the  operation  of  one-key  recovery.  It  could  continue  to  select  the  parameter  recovery 

items by pressing key

▼and the selection range is H0

H7

press key 

  to execute the parameter 

recovery and then exit

if there is no parameter recovery operation within 30S,it will automatically exit 

from the mode without recovery of parameters.   

Note: It requires a reliable power supply during this operation, or else, you need to operate it again after 

power on the controller and get a reliable power supply. 

H0 

Give up parameter recovery

no change of each parameter, no 

display of parameter recovery success code 

dr

 

H1 

Recovery parameter value H1, recovery success display 

dr

 

H2 

Recovery parameter value H2, recovery success display 

dr

 

H3 

Recovery parameter value H3, recovery success display 

dr

 

H4 

Recovery parameter value H4, recovery success display 

dr

 

H5 

Recovery parameter value H5, recovery success display 

dr

 

H6 

Recovery parameter value H6 recovery success display 

dr

 

H7 

Recovery parameter value H7 recovery success display 

dr,

 it is 

used specially for production testing, user should not use it. 

7.  Control output 

7.1 Compressor

 

        Normal status

 

  when  the  cabinet  temperature  is  higher  than  temperature  setting  (St)  +  Temperature  hysteresis(C1), 

and finish the compressor start Min interval, the compress will start

 

When the cabinet temperature is lower than temperature setting (St), the compressor will close. 

  Cabinet sensor failure: 
When parameter item A1=0, the function of “Run/stop in a proportional time” is closed, the compressor 
closes

 

   

When parameter item A1=1, the function of “Run/stop in a proportional time” opens, the compressor 

will run and stop periodically according to the set time proportion (Start duration A2 and Stop duration 

Summary of Contents for BC145V

Page 1: ...Refrigerators Freezers Instruction manual BC145V GK60 GN60 SD1381 SDN1381 PLEASE READ THE OPERATION MANUAL BEFORE USING SAVE THIS MANUAL FOR LATER USE ...

Page 2: ... all packaging away from children Dispose of the packaging in accordance with the regulations of local authorities If the power cord is damaged it must be replaced by a agent or a recommended qualified technician in order to avoid a hazard This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge un...

Page 3: ...2 2 123 158 4 others 6 2 4 Cabinet temperature control range 50 90 or 58 194 2 5 Power supply 220VAC 50 60Hz 2 6 Power consumption 3W 2 7 Output capacity Refrigeration 30A 240VAC normal open directly drive a single phase 1 5HP 220VAC load or optional 17A 240VAC normal open directly drive a single phase 1 0HP 220VAC load Defrost or lighting relay 10A 240VAC normal open directly drive heater strip M...

Page 4: ...e Press 3s to start forced defrost Exit from one key recovery status 5 2 Keys operation 6 2 1 Parameter adjustment In the status of temperature measuring and controlling press Set key for three seconds to enter user menu display St press Set key again display the parameter value of St then you could set temperature value by pressing or key When display St press key display Po press Set key display...

Page 5: ... key to execute the parameter recovery and then exit if there is no parameter recovery operation within 30S it will automatically exit from the mode without recovery of parameters Note It requires a reliable power supply during this operation or else you need to operate it again after power on the controller and get a reliable power supply H0 Give up parameter recovery no change of each parameter ...

Page 6: ...t and defrost method is electrical heating defrost U3 01 at this time no defrost relay and defrost method is off cycle defrost 7 3 Lighting U3 01 K2 relay works as lighting relay press to open the lighting and press key again to close the lighting 7 4 Alarm reminding When the cabinet temperature sensor failure display E1 in digital tube When the evaporator sensor failure display E2 in digital tube...

Page 7: ...oodstuffs in the appliance when it has reached the correct operating temperature Do not place uncovered hot food or liquid inside the appliance Wrap or cover food where possible Do not obstruct the fans inside the appliance Avoid opening the doors for prolonged periods of time Lock Unlock the Doors A lock is fitted to the doors to ensure foodstuffs are kept secure within your appliance Use the key...

Page 8: ...y Check doors are shut and seals are not damaged Appliance is located near a heat source or air flow to the condenser is being interrupted Move the refrigerator to a more suitable location Ambient temperature is too high Increase ventilation or move appliance to a cooler position Unsuitable foodstuffs are being stored in the appliance Remove any excessive hot foodstuffs or blockages to the fan App...

Page 9: ...oved and environmentally safe recycling process For further information on how to dispose of this product correctly contact the product supplier or the local authority responsible for waste disposal in your area Parts have undergone strict product testing in order to comply with regulatory standards and specifications set by international independent and federal authorities Products have been appr...

Reviews: