![Topaz TZ-12AB Owner'S Manual Download Page 8](http://html1.mh-extra.com/html/topaz/tz-12ab/tz-12ab_owners-manual_1127943008.webp)
9
Portable Air Conditioners
Problem
Cause
Remedy
Insufficient cooling
Insufficient airflow through evaporator
See Preventive Maintenance section of this manual.
coil due to:
-Dirty air filter in unit
-Clean filter.
-Dirty evaporator coil
-Clean filter with a vacuum cleaner and hose.
-Ice on evaporator coil
-Defrost. Run on fan only.
-Obstructed air intake
-Remove obstruction.
-Low refrigerant
-Repair leak in system.
-Improper Motor Rotation (TZ-60AB4 only) Reverse two of the three power supply leads
(See TZ-60AB4. Phase wiring instructions pg. 6)
Unit improperly sized
Check to assure unit is sized for load.
Add supplemental unit if required.
Noisy operation
Copper tubing vibrating
Adjust by bending slightly to firm position.
Segregate tubes touching cabinet or each other.
Loose cabinet or internal component
Check and tighten loose screws.
Machine vibrating - out of level
Level unit base.
Blower motor bearing defective
Replace blower motor.
Water leaks from pan
Leaky drain pan
Replace pan.
Drain plugged
Check and clear obstruction.
Loose evaporator, drain, or condensate
Tighten connections.
pump hose
Defective condensate pump or excessive
If elevation exceeds 20-ft, a larger pump is
lift on pump
required. Pump does not operate properly if
combination of lift height and length of drain line
exceeds 20-ft.
Change pump, if defective.
Unit not on level surface.
Level.
Evaporator coil freezing
Evaporator exhaust screen obstructed
Remove obstruction.
and shuts unit down
Freeze protection control not operating
Check that control is securely attached to
correctly (TZ-12AB, 24AB, 36AB, 60AB
evaporator coil’s outlet and that insulation
and 60AB4 only)
is in place.
Check wiring connections to freeze
protection control.
Unit not delivering
Drive belt damaged or not
Check condition and adjustment of evaporator
proper air flow
adjusted correctly
and condenser fan belts and sheaves.
TZ-60AB4 only
Adjust belts for 3/16-in deflection. (See pg. 7)
Summary of Contents for TZ-12AB
Page 13: ...TOPAZ Owner s Manual Wiring Schematic TZ 12AB TZ 24AB and TZ 36AB Portable Air Conditioners ...
Page 14: ...15 Wiring Schematic TZ 18AB Portable Air Conditioners ...
Page 15: ...TOPAZ Owner s Manual Wiring Schematic TZ 60AB Portable Air Conditioners ...
Page 16: ...17 Portable Air Conditioners Wiring Schematic TZ 60AB4 ...
Page 17: ...Portable Air Conditioners ...