@ToolkitRC 2020
24
Other functions
1. Firmware upgrade
After connecting the M4Q to the computer with the USB
data cable in the box, the computer will recognize a USB
drive named Toolkit. Download the upgrade file
app.upga on the official website. To update copy and
past the new file and overwrite the files in the USB to
upgrade the firmware.
2. Automatically continue charging
When a battery is fully charged, after unplugging the
battery for 2 seconds, connect to the next battery, the
device will automatically continue to charge, you can
start and stop this function in the settings menu.
3. Fan level
When the internal temperature of the device exceeds
42°C, the fan turns on half-speed air volume to reduce
noise. When the internal temperature exceeds 50°C, the
fan turns on full-speed air volume to enhance heat
dissipation.
6. Manually calibrate the voltage
In the shutdown state, press and hold the [Scroll
Wheel] without releasing, connect the power supply, and
the system will enter the manual voltage calibration
function. Use a voltmeter to measure the actual voltage
of each battery, move the cursor to the corresponding
voltage value, modify the voltage value to be consistent
with the voltmeter value, and achieve calibration. After
the calibration is completed, move the cursor to save,
short press once, the buzzer will beep for a long time,
and the save is successful. Just exit or shut down.