31
Display
Description
3 0 0
C
2 0
REAL
Timer function
• In this example a timer has been set for 20 seconds.
• The air gun will stop heating after 20 seconds then blow non-heated air
until it has been cooled to <100 °C.
Standby
• In this state you can adjust settings without activating the air gun.
• The air gun will enter standby when the temperature drops <100 °C.
• The air gun will start working after removing the handle from the holder.
o f f
Auto-sleep
• The workstation will enter sleep mode after 30 minutes in standby mode.
• Press any button to resume use.
11. Adjusting settings
a) Navigating the settings menu
Button
Description
1
Up
2
Save value and exit settings menu
3
Down
▲
Increase value
▼
Decrease value
To enter the settings menu:
1. Press and hold buttons
1
and
3
at the same time for more than 3 seconds.
If a passcode has been set, “PSd” will show on the display. You must first enter the passcode to access the
settings menu. For further information, see section “g) Setting a passcode “PSd”” on page 33.
2. Press shortcut key
1
or
3
to navigate the settings menu.
3. Press
TEMP
▲or ▼to adjust values.
4. Press shortcut key
2
to save settings and exit the settings menu.