![Tool-Co BDG250 Operating Manual Download Page 5](http://html1.mh-extra.com/html/tool-co/bdg250/bdg250_operating-manual_1126696005.webp)
MANUAL
OPERATION
The floor grinder is designed to be used either wet or dry. If the floor is being
ground dry, ensure a suitable industrial vacuum is connected and that the
operator is wearing suitable breathing respiratory equipment. Contact your
local work place health authority to ensure that their requirements regarding
respiratory equipment are being met.
STARTING THE GRINDER
1. Check the grinding plate being used is suitable for the material being ground
AND THAT THEY ARE CORRECTLY BALANCED.
2. Check that the grinding plates being used are in good order and properly
attached, with all countersunk bolts firmly in place. Check this occasionally
during use, as they can work loose during operation.
3. Check that the grinding plate is adjusted so that it sits level on the ground.
4. Check that all nuts and bolts on the folding handle latch are tight and firm.
5. Raise the grinding plates from the floor.
6. Start the motor by pressing the black switch on the starter box.
7. Lower the grinding plate and commence grinding.
STOPPING THE GRINDER
1. De-press the red stop button on the starter box.
NOTE:
1. By turning and pushing the handles, you can fix the vertical grinding position.
2. Adjust the axle’s width to improve grinding stability.
1
2
Pg.3