4-3 Adjustment of valve position

<Full-close position adjustment procedure 

(Full-close side adjustment)>

(1)  Set position to open on this product. Check that 

the position indicator

 ㉑

 indicates O (Open). 

(2)  Remove the air pipelines and set inside pressure 

to atmosphere.

(3)  Release the hexagon nut  .

(4)  Use a hexagonal wrench to rotate the hexagon 

stop screw   to the required angle. The hexagon 

stop screw   is rotated clockwise, and the valve 

full-close position becomes shallow. Please refer 

to [Table 1] for rotation angles.

Hexagon stop screw 

Hexagon stop screw 

Seal washer

Position indicator 

Opening adjustment bolt

Closing adjustment bolt

Single-acting type cylinder (7F)

For pressure-closing single-acting type cylinders 

(7F), the opening adjustment position is different 

from this figure. Perform the full opening side 

adjustment by adjusting the bolt at the [OPEN] 

side of the base plate. The tightening torque 

should be the torque of "Closing side stopper bolt" 

in [Table 2] for both the open and close sides.

Do not release the hexagon nut   and the hexa-

gon stop screw   to prevent danger. [Fig. 4]

Table 2 Stopper bolt tightening torque

Hexagon nut

Hexagon stop screw

  

   

Type 

T35

 T85  T200  T380  T750

  

Model no. 

  

T85S  T200S  T380S T750S

 Close side   7E 

• 

7G 

• 

7F 2  1.3 

0.9 

0.6

 

Open side

   7E 

• 

7G 2.6  1.9  1.7 

1.6  1.5

  

 

7F 

1.3 

0.9 

0.6

<Full-open position adjustment procedure 

(Full-open side adjustment)>

(1)  Set position to close on this product. Check that 

the position indicator 

 indicates Close.

(2)  Remove the air pipelines and set inside pressure 

of the product to atmosphere.

(3)  Release the hexagon nut  . [Fig. 3]
(4)  In case of deformation or breakage of the seal 

washer  , replace it with a new seal washer. 

Otherwise, air leakage may occur.

(5)  Use a hexagonal wrench to rotate the hexagon 

stop screw   to the required angle. The hexagon 

stop screw   is rotated clockwise, and the valve 

full-open position becomes shallow. Please refer 

to [Table 1] for rotation angles.

<How to restore after adjustment>

(1) Hold the hexagon stop screw   or   in position 

with a hexagonal wrench, and tighten the hexagon 

nut   or   with a spanner. Please refer to [Table 

2] for the tightening torque.

(2) Apply air pressure to the cylinder and check that 

the rotation angle of the output shaft is obtained, 

and there is no air leakage.

(3) If readjustment is required, repeat the above 

procedure from (1).

Note) Full-close/full-open position is adjusted when 

shipped.

 

                   Open-side stopper bolt     Close-side stopper bolt 

 

Type

 

Bolt  Torque Bolt Torque

 T35 

M8 

20 Nm 

M8 

20 Nm

 T85 

• 

T85S 

M8 

20 Nm 

M10 

35 Nm

 T200 

• 

T200S 

M10 

35 Nm 

M12 

53 Nm

 T380 

• 

T380S 

M12 

38 Nm 

M16 

115 Nm

 T750 

• 

T750S 

M16 

115 Nm 

M20 

200 Nm

[Fig. 3]

[Fig. 4]

Double-acting type cylinder (7E)

Single-acting type cylinder (7G)

Closing angle adjustment 

hexagon nut   

Opening angle 

adjustment 

hexagon nut 

CAUTION

Table 1 Shaft rotation angle given by one turn of the stopper bolt (degrees)

Summary of Contents for T-DYNAMO 7E

Page 1: ...pe cylinder 3 2 Expanded view Single acting type cylinder 3 3 Output torque curves 3 4 Air consumption 4 CYLINDER SYSTEM CONFIGURATION 4 1 System configuration 4 2 Speed controller 4 3 Adjustment of v...

Page 2: ...and inspection of this product If there are any questions please contact our sales department Reference values and limit values for operation maintenance and inspection specified in this instruction...

Page 3: ...packing 2 The shaft penetrates the chamber of the case The yoke is fitted in the hole across the shaft in such a way that it allows it to slide in the hole The top of the yoke is connected with the p...

Page 4: ...ting type cylinder 7F 7G 1 3 Type description 1 4 Standard specifications Double acting type cylinder 7E Single acting type cylinder 7F 7G T85 T 8 5 S The output torque of single acting type differs f...

Page 5: ...2 1 3 Fail safe design When the unit is used for the point where fail safe design is required adopt a method where the system responds in a way that will cause no harm using a single acting type cylin...

Page 6: ...ocation The following measures should be taken depending on the atmosphere of the location where this product is installed Locations which are exposed to gas containing salt corrosive gas chemical sol...

Page 7: ...le paying attention to the following items If dents or scratches are made on impact to ensure safety stop using the product and replace the product This product attachments and pneumatic pipelines sho...

Page 8: ...atic devices in which the pneumatic pipeline inlet of this product or the end of the plant pipeline is connected with a long pipeline air supply amount and air supply pressure may be insufficient for...

Page 9: ...ion check that the manual gear is at the position of automatic operation and the bypass valve is closed They are not returned automatically 2 4 8 Others If air supply is stopped for a long period of t...

Page 10: ...be checked that opening of the valve and the opening of this product are the same If the openings are not the same opening and closing operation is performed in the reverse way 2 5 6 Replacement of c...

Page 11: ...ng washer cover 1 2 8 14 Bearing 2 1 T35 only 47 Hexagon socket head cap screw cover 1 2 8 15 Bearing 3 lower shaft 1 49 Hexagon socket head cap screw base plate 4 T35 2pcs 16 Bearing 4 upper shaft 1...

Page 12: ...2 1 37 Stopper bolt 1 T750S only 8 Base plate 1 42 Spring 2 9 Bearing 2 43 Spring guide 2 11 Indicator plate 1 44 Hexagon bolt spring guide 2 13 Bearing 1 shaft piston 2 45 Spring washer spring guide...

Page 13: ...e cylinder air consumption N VS Single acting type cylinder air consumption N A B Cylinder capacity P Operating pressure MPa N Operating frequencies in a given time 1 round trip 1 CD Double acting typ...

Page 14: ...box This switch box is for remotely displaying the open close status of the valve Positioner unit E P Positioner and P P Positioner This unit features a function that allows total control of the valve...

Page 15: ...ht knob and adjust the closing speed with the left knob For single acting type cylinders only the speed when operating air is discharged can be adjusted Adjust the speed only with the right knob For p...

Page 16: ...sition becomes shallow Please refer to Table 1 for rotation angles Hexagon stop screw Hexagon stop screw Seal washer Position indicator For pressure closing single acting type cylinders 7F the opening...

Page 17: ...red angle The hexagon stop screw is rotated clockwise and the valve full open position becomes shallow Please refer to Table 1 for rotation angles How to restore after adjustment 1 Hold the hexagon st...

Page 18: ...w Knob Approx 10 mm Automatic operation Bypass valve closed Manual operation Bypass valve open Do not use a spanner a monkey wrench or the special lever in the following cases as it could result in a...

Page 19: ...en the cross recessed head screw to lock the knob Reconnect the solenoid valve or the air pipeline When the manual gear and the manual screw handle are not installed Remove spanner monkey wrench or sp...

Page 20: ...h the attachment part plate and the filter regulator with the attachment part clamp 3 Fasten the attachment part clamp with screws long Fig 12 Installation procedure P31EA22MMBNNP Rc1 4 0 4 0 7MPa Max...

Page 21: ...ed on cover 1 of this product Fig 13 2 The solenoid valve installation orientation depends on whether the valve is opened or closed when energized To reverse the orientation remove the solenoid valve...

Page 22: ...ous situation 1 Set the position to full close on this product 2 Loosen the cover holding bolts at the four corners of the limit switch box and remove the top cover Fig 15 3 Pull the top cover out upw...

Page 23: ...tic pipelines and electric wiring from this product 2 Remove the bolts and spring washers that fasten this product to the valve then take out this product from the valve Removal of the unit from the v...

Page 24: ...1 Q ty 2 pcs for each 4 pcs for each Type 35 T85 T750 T85S T750S 7 Take out the yoke and the bearing from the case Please note that the type and quantity of the bearing of T35 is different from those...

Page 25: ...screw in the bolts to the length shown in Table 8 and tighten them Fig 23 Not required for T750S 7 Loosen the hexagon socket head cap screws and alternately When the cover and the bolts for disassem...

Page 26: ...is a mounting direction for the yoke Assemble the unit so that the face stamped with UP mark of the yoke faces to the upper side of the cylinder Note If F mark is stamped on the yoke instead of UP ma...

Page 27: ...sure the free movement of the piston Fig 33 Insert the connecting pin after making sure that the pin hole of the yoke and the pin hole of the shaft are aligned Insert the connecting pin into the tappe...

Page 28: ...le 12 Grease application amount Thrust plate Case Stopper Shaft Thrust plate Base plate Hexagon socket head cap screws Spring washer For T35 Apply liquid gasket to the designated area on the base plat...

Page 29: ...t wrong cover installation causes defective operation such as air leakage Forcible assembly of single acting type cylinders such as uneven tightening of the hexagon socket head cap screw to mount the...

Page 30: ...hten the bolts for disassembly until the dimension A in the figure becomes the distance where the hexagon socket head cap screws which had been mounted to the product can engage the case And then inst...

Page 31: ...e knob of the speed controller Supply pressure of compressed air etc is high Decrease the air supply pressure within the range of the specifications of this product Speed controller is closed too much...

Page 32: ...aused by fire flood earthquakes fall of rocks and other acts of God 12 The failure was caused by other reasons which are not our responsibility In addition the forgoing warranty is only applicable to...

Reviews: