PAGE 9
MACHINE SETUP
CONNECTING BATTERIES
Your machine is equipped with (2) 12-volt/115 AH, or (2)
12-volt/165 AH, Deep Cycle, Batteries, which form a 24
volt system.
(SEE PICTURE BELOW FOR CORRECT CABLE CONNECTIONS.)
1. Turn all switches to the off position and remove key
(if machine is equipped with optional key switch).
2. Turn on main power switch and check the battery
condition meter to ensure correct installation.
Charge batteries if needed. (SEE BATTERY CHARGING.)
WARNING!
Batteries are a possible environmental hazard.
Consult your battery supplier for safe disposal methods.
NOTE: Orientation of batteries is critical for cables to reach!
2. Loosen the two knobs
"B"
on the squeegee
and slide them into the slots in the squeegee
mounting plate. (SEE
BELOW
)
ATTACHING SQUEEGEE
1. Lower the squeegee mounting plate by
rotating the lift lever
"A"
clockwise.
(SEE
BELOW
)
4.
You may have to adjust the squeegee pitch.
(SEE ADJUSTING SQUEEGEE ON NEXT PAGE.)
*BATTERY CABLE CONNECTIONS*
2. Tighten the two knobs, and connect the
vacuum hose
"C"
from the machine to
the squeegee. (SEE
BELOW
)
24-Volts
A
B
B
C
UNCRATING MACHINE
CAREFULLY CHECK THE CRATE FOR ANY SIGNS OF
DAMAGE AND THAT THE BATTERIES ARE IN THE UNIT.
TO UNCRATE THE MACHINE, REMOVE BANDING FROM
AROUND THE CRATE. TAKE OFF THE TOP AND SIDES
AND DISPOSE OF PROPERLY. REMOVE BRACKETS
(A)
FROM MACHINE WHEELS. REMOVE BOLTS
(B)
FROM
PALLET THEN REMOVE BOARD
(C)
. CAREFULLY ROLL
THE MACHINE OFF OF THE BASE. NOTIFY THE CARRIER
IMMEDIATELY IF CONCEALED DAMAGE IS DISCOVERED
.
(SEE BELOW)