All hose connections must be put together with hose clamps and double secured in the opposite
direction.
The electrical connection should be made with a constant energized, protected cable directly
to the connection box of the plant. The cable designations are ALWAYS as follows (valid for the
entire plant):
The ventilation must be carried out by means of the enclosed carbon filter to the outside.
Cable number 1
red
Plus
+
Cable number 2
blue
/black
Minus -
The purification process produces among other things carbon dioxide and
methane gases, which is why the vents must be discharged to the outside and
never be discharged into the interior of the boat!
MAKING THE CONNECTIONS
INSTALLING THE REMOTE CONTROL
The system cable of the remote control is color-coded
and is connected directly to the system terminal in the
switch box of the plant. Connect the remote control
according to the following table. Use the ferrules for
correct installation.
Color
code
cable
Terminal number
Remote control
(1 is on the left)
Terminal coding
switch box
Orange
1
or
Blue
2
bl
Green
3
gn
Yellow
4
ye
Pink
5
pi
Brown
6
br
Violett
7
pu
Black
8
bk
White
White
9
wh
The remote control re-
quires a panel cut-out of
65 mm x 65 mm or
80 mm hole circle; the
base plate measures
95 mm x 95 mm and is
attached to the corners
with the supplied small
wood screws.
Please observe the
required installation depth of 45 mm. The remote
control can also
be mounted in a
80 mm cavity wall
box.