Parts Sheet #8100-4115_05_MXP16P_ps
MXP16P
Switches / Maintenance – 5
Parts Sheet #8100-4115_05_MXP16P_ps
Parts Sheet #8100-4115_05_MXP16P_ps
Options - List of Parts
LUBRICATION AND MAINTENANCE
All Tolomatic MX Band Cylinders are prelubricated at the factory. To ensure
maximum cylinder life, the following guidelines should be followed.
1. Filtration
We recommend the use of dry, filtered air in our products. “Filtered
air” means a level of 10 Micron or less. “Dry” means air should be
free of appreciable amounts of moisture. Regular maintenance of
installed filters will generally keep excess moisture in check.
2 External Lubricators (optional)
The factory prelubrication of Tolomatic Band Cylinders will provide
optimal performance without the use of external lubrication. However,
external lubricators can further extend service life of pneumatic
actuators if the supply is kept constant.
Oil lubricators, (mist or drop) should supply a minimum of 1 drop per
20 standard cubic feet per minute to the cylinder. As a rule of thumb,
double that rate if water in the system is suspected. Demanding con-
ditions may require more lubricant.
If lubricators are used, we recommend a non-detergent, 20cP @
140˚F 10-weight lubricant. Optimum conditions for standard cylinder
operation is +32˚ to +150˚F (+0˚ to 65.5˚C).
NOTE:
Use of external lubricators may wash away the factory installed
lubrication. External lubricants must be maintained in a constant sup-
ply or the results will be a dry actuator prone to premature wear.
3. Sanitary Environments
Oil mist lubricators must dispense “Food Grade” lubricants to the air
supply. Use fluids with ORAL LD50 toxicity ratings of 35 or higher
such as Multitherm
®
PG-1 or equivalent. Demanding conditions can
require a review of the application.
4. Cushion Adjustment
Adjust the Cushion Needles in the Cylinder Heads carefully to obtain
optimum deceleration for your particular application. If there are
questions on proper adjustment, please consult Tolomatic.
SWITCH WIRING DIAGRAMS AND LABEL COLOR CODING (CE and RoHS Compliant)
NORMALLY
CLOSED
BRN
BLU
+
-
LOAD
NORMALLY
CLOSED
BRN
BLU
+
-
LOAD
or
NORMALLY
OPEN PNP
(SOURCING)
BRN
BLK
+
SIGNAL
LOAD
BLU
-
NORMALLY
OPEN NPN
(SINKING)
BRN
BLK
+
SIGNAL
LOAD
BLU
-
NORMALLY
CLOSED PNP
(SOURCING)
BRN
BLK
+
SIGNAL
LOAD
BLU
-
NORMALLY
CLOSED NPN
(SINKING)
BRN
BLK
+
SIGNAL
LOAD
BLU
-
NORMALLY
OPEN
BRN
BLU
+
-
LOAD
NORMALLY
OPEN
BRN
BLU
+
-
LOAD
or
TY • TK
SOLID STATE • NORMALLY OPEN • PNP
NY • NK
REED • NORMALLY CLOSED
QUICK DISCONNECT MALE PLUG PINOUT
#8100-9080 QUICK DISCONNECT
FEMALE SOCKET PINOUT
RY • RK
REED • NORMALLY OPEN
KY • KK
SOLID STATE • NORMALLY OPEN • NPN
PY • PK
SOLID STATE • NORMALLY CLOSED • PNP
HY • HK
SOLID STATE • NORMALLY CLOSED • NPN
BROWN (+)
BLUE (-)
BLACK
(SIGNAL)
BLUE (-)
BROWN (+)
BLACK
(SIGNAL)
SWITCH DETECTION POINT
Dimensions in inches [brackets indicate dimensions in millimeters]
16, 25, 32
MOUNTING DIMENSIONS
SWITCH DIMENSIONS
40, 50, 63
1.18 [30]
.31 [8]
Ø.28 [7]
.95 [24.1]
1.26 [32.1]
.51 [13]
DETECTION POINT REED
DETECTION POINT
SOLID STATE
13.35 [339]
M8x1
M8x1
197 [5000]
197 [5000]
_
K
- QD (Quick-disconnect) switch
8100-9080 - QD Cable
_
Y
- direct connect
U
SWITCHES SIT BELOW
TUBE EXTRUSION PROFILE
SWITCHES SIT BELOW
TUBE EXTRUSION PROFILE
V
U
Ø.35
[9]
W
V
X
Switches for MX:
• Include retained mounting hardware
• In slot, sit below extrusion profile
• Same for all sizes and bearing styles