6.
Installation
6.1. Installation cautions
DO NOT use locking pliers to over tight the DRAIN PIPE connection.
Before installation, MUST read all the install cautions in this manual, on page 4.
Selecting the proper steam generator
In order to achieve comfort and relaxation, as well as energy efficiency, the selection of the
correct steam generator model and size are as critical as design of the steam room itself. The
power supply and circuit protector should be carefully checked to match the parameters of the
generator. Please referring to the table 2 & its notice and select the suitable model for your
specification.
6.2. Installation of steam generator body
6.2.1. Cautions
Switch off all power supply before installation, and check whether you have the correct model
for your steam room according to table 2 & its notice .
A manual resetting 120
℃
temperature control switch is installed in the steam generator for
over-heat protection. If temperature of inner tank exceeds 120
℃
accidentally, the switch will
automatically disconnect power supply to heating elements. In this case, it is necessary to
disconnect the power supply to steam generator, and then carefully check heating elements,
water level sensor, relay on sub-board and water supply pipeline after steam generator
completely cooling-down. The temperature switch could only be manually reset after the fault
has been located and solved.
Do not install the generator outdoors, in wet/moist place, freezing, or corrosive place. Do not
install the generator near to inflammables such oil paint, diluents and fuel. Be alert to the steam
pipeline and safety valve since the high temperature of steam is dangerous to customers.
Generator must be level installed.
The generator should be installed in a dry and well-ventilated place. It can be installed either on
the wall or on the ground, but must be well fixed. Install the generator as close to steam room as
possible, such as in the closet, under the washing basin or in the basement. (Refer to figure 3).
6.2.2. Cautions
The controller wire and temperature sensor wire should NOT be parallel to or intersect with
the power wire. The temperature sensor should NOT be installed on the side of the wall
which is behind the door, when the door is opened and the controller should NOT be
installed in any moist place.
6.2.3. Installation of controller
The controller should be installed with height of 1.2 m outside the steam room but nearby