________________________________________________________________________________
TOLO SAUNA
www.tolosauna.com
3
The solenoid valve can endure maximum 0.8MPa (8kg/cm2) water pressure. To protect the
solenoid valve from extremely high water pressure, please turn down the inlet slightly or
install water pressure relieving valve .
Do not install saddle-backed or needle valves on the inlet. Please dredge and clean the pipe
before installation.
No block valve should be installed in the steam pipelines. Strictly no blocked or blended pipe,
otherwise will have negative effect on the flow of steam and condensate. The steam pipelines
should be installed with a slight angle so that the condensate can flow back to the generator
or the steam head.
Steam generator should be installed indoor to avoid frozen. The generator should be installed
and leveled with the arrow pointing upward at an easy-access place, otherwise do not switch
on.
The steam pipeline must be copper pipes or stainless steel pipes, all other material such as
plastic, acrylic should not be used since they cannot endure 150
℃
or higher temperature.
All inlet and apertures should be sealed to prevent any leakage of steam and to protect the
generator and customers.
Don’t directly drain to the steam room, as water from the water tank is very hot and may
cause serious scald and damage the steam room.
All inlet water pipes and steam pipelines should be built according to the National Standard
and this should be done before sealing the wall.
4.
Parameters
4.1. Models, parameters and dimension
(Only apply to European style voltage and phase)
Table 2
Model
Power
(kW)
Phase
Heating elements
(N*kW)
Voltage/Current
(V/A)
Power
wire
(N*mm
2
)
Breake
r
(A)
Room
volume
(m
3
)
Dimension
(L*W*H)
(mm)
E-30
3.0
1
2*1.5
220-240/13.6
3*2.5
16
2
~
3
230*103.5*13
20
E-40
4.0
1
2*2.0
220-240/18.2
3*2.5
25
3
~
5
E-45
4.5
1
1.5+2.0
220-240/20.5
3*2.5
25
3.5
~
5.5
E-50
5.0
1
2*2.5
220-240/22.7
3*2.5
32
4
~
6
E-60
6.0
1
2*3.0
220-240/27.3
3*4.0
40
5
~
7