11
GOOD PART RELAY
TIME GOOD
0 (value) ENTER
REJECT RELAY
TIME REJECT
0 (value) ENTER
DECREASE RELAY
TIME DE
0 (value) ENTER
INCREASE RELAY
TIME IN
0 (value) ENTER
PRESET COUNTERS To display press:
To change press:
SHUTDOWN RELAY
TIME REJECT
. (0-9) ENTER
DECREASE RELAY
TIME DE
. (0-9) ENTER
INCREASE RELAY
TIME IN
. (0-9) ENTER
ZONE COUNTERS
To display press:
REJECT HI ZONE
COUNT REJECT HI
REJECT LO ZONE
COUNT REJECT LO
DECREASE GOOD ZONE
COUNT GOOD DE
INCREASE GOOD ZONE
COUNT GOOD IN
OK ZONE
COUNT GOOD GOOD
DECREASE ZONE COUNT
COUNT DE DE
RELAY COUNTERS
To display press:
GOOD PART
COUNT GOOD
REJECT
COUNT REJECT
DECREASE
COUNT DE
INCREASE
COUNT IN
INCREASE ZONE COUNT
COUNT IN IN
CHANGE FROM 0 TO 2 CHANS & BACK:
LOW LOW LOW . 0 or 2 ENTER
RESETTING ALARMS:
RESET RESET RESET
CLEARING ANY DATA:
CLEAR
- clears display to zero
CLEAR MEMORY: press and hold
CLEAR
- then press
RESET RESET RESET
DIAGNOSTICS: each time
DIAG
is pressed new diagnostic info is shown when #=1, battery
voltage is displayed
I. GENERAL DESCRIPTION -
Refer to figure 7
Summary of Contents for MoniTTor N269
Page 1: ......
Page 2: ......
Page 3: ...N269 Installation and Operations Manual...
Page 4: ...THIS PAGE INTENTIONALLY LEFT BLANK...
Page 9: ...2...
Page 10: ...3...
Page 11: ...4...
Page 13: ...6...
Page 14: ...7...