6-A 

Front Panel Description 

 

 

 

 

 

 

 

 

POWER 

Main power switch to turn AC power on and off.   

LED (green) lights when turned on. 

OPER. 

OPERATE/STAND-BY switch. At OPERATE, the amplifier is 

ready to go into ON AIR (TX) mode and at STBY, it is on 

STAND-BY mode. 

METER

 

To change the multimeter scales. Meter reads Pr, Vd, and Id, 

and ALC. 

BAND-AUTO/MAN’L 

 

To select band switching methods AUTO or MANUAL. When 

using AUTO, the manufacturer for the transceiver in use 

should be selected. When the band data cable is not used, 

MANUAL should be selected. (See page 9, 

SELECT and 

CONT for Band Data cable Connection) 

BAND-MAN’L 

Rotary switch for band change in manual mode. While the 

transceiver is on Receive (RX) mode, turn to select the 

desired frequency band to operate. The switches will not work 

when the transceiver and the amplifier are in Transmit (TX) 

mode.  

METER(P

F

Meter to read forward output power, P

F

. Full scale is 2.5 kW, 

and it reads average power. 

Summary of Contents for HL-2.5KFX

Page 1: ...INSTRUCTION MANUAL HF LINEAR POWER AMPLIFIER MODEL HL 2 5KFX...

Page 2: ...te when powered The amplifier is cooled by forced airflow Several inches of clearance on the top and the rear wall are necessary to allow for smooth air intake into the fan Do not block the air vents...

Page 3: ...eter reading The internal potentiometers for RF power detector protection circuits FET bias voltage circuit etc are precisely adjusted at the factory and should not be altered Doing so would require r...

Page 4: ...bands automatically as the data signal is received from the associated HF transceiver s frequency bands 3 3 The amplifier s main PA section includes 2 high power MOS FET ARF1500 s by Microsemi resulti...

Page 5: ...mployed The AC power is shut down if the top cover is removed and the automated safety interlock is activated 3 9 An analog multimeter allows the operator to monitor Pr Reflected power Vd Drain voltag...

Page 6: ...Method Forced Air Cooling MPU PIC 18F452 I P Multi Meter Output Power Pf 2 5 kW Reflected Power Pr 250W Drain Voltage Vd 150V Drain Current Id 40A Input Output Connectors UHF SO 239 with low loss Tef...

Page 7: ...tages other than 240 V For your safety before making these adjustments be sure to pull the AC plug from the AC outlet to avoid injury AC Line Tap 1 Tap 2 200V 195V 205V 0 V 200 V 210V 205V 215V 10 V 2...

Page 8: ...AUTO or MANUAL When using AUTO the manufacturer for the transceiver in use should be selected When the band data cable is not used MANUAL should be selected See page 9 SELECT and CONT for Band Data c...

Page 9: ...antenna situation high drain current may flow into FET s If 25 A is exceeded this LED flickers and or lights to indicate that high ID is being drawn This light does not necessarily mean a failure of...

Page 10: ...tenna Tuner HC 1 5KAT SELECT Switch to select the transceiver manufacturer i e CI V for ICOM CI V I for ICOM DC Voltage Y for Yaesu K for Kenwood Aux1 3 for three auxiliary positions of N C no connect...

Page 11: ...s higher than 100 W See page 16 Section 9 ALC Connection Also consult your HF transceiver s user manual SEND RCA Jack Connect the control cable from the ACC terminal or SEND TX GND etc of the transcei...

Page 12: ...A J ALC socket 10V max SEND Transceiver Short at TX RCA J PTT relay Open at RX 12V 40mA TUNER Tuning Control Auto Tuner Band tracking signal DIN7J GND EVENT HC 1 5KAT FREQ CONT socket INPUT UHF SO239...

Page 13: ...7 2 Technical Information Equivalent Circuit of SEND Terminal Equivalent Circuit of ALC Output 12...

Page 14: ...aluable final power FET devices 8 1 Various Status There are four modes to be displayed on LCD STBY Standby Mode This mode is for AC Power ON and OPER Switch at STBY position Amplifier is in a through...

Page 15: ...If SWR is 1 8 or higher at band center the antenna has to be adjusted for lower SWR As an alternative an antenna tuner may be inserted 8 2 4 While keeping OPER STBY switch at STBY position turn the PO...

Page 16: ...the amplifier check the antenna SWR Vd AC line voltage or try to reduce the drive level To reset turn off the OPER STBY switch once then back on again Note that some protection modes need to reset th...

Page 17: ...e to the ALC or EXTERNAL ALC jack of the transceiver External ALC input is sometimes available at one of the pins of the ACC socket of the transceiver as well 9 2 At first turn ALC ADJ full clockwise...

Page 18: ...facturer Turn off AC powers of both the amplifier and the transceiver when you connect this data cable Be sure to confirm the auto band set on each band after you finish above settings Manual Band set...

Page 19: ...Y LCD YSU Wiring Fig C Transceiver Setting None 10 4 Kenwood RS 232C HL 2 5KFX Setting SELECT K LCD KEN Wiring Fig D Transceiver Setting Speed 9600 bps Stop bit 1 bit See Kenwood radio manual for the...

Page 20: ...R DRIV ceeded 150 W 1 OPER 2 B Amp gain is less than five times 1 OPER Or when amp out of order 3 O er current PROT OVER ID ID drain exceeded 35 A 1 OPER 4 F q Inhibit PROT INHBT FREQ Driven freq rang...

Page 21: ...turned on for itself right after the cooling inter locked circuits built in th They directly shut down AC power line for the primary of the power transformer and if shut down AC power lamp green LCD d...