![Tokyo Hy-Power HL-2.5KFX Instruction Manual Download Page 12](http://html1.mh-extra.com/html/tokyo-hy-power/hl-2-5kfx/hl-2-5kfx_instruction-manual_1125169012.webp)
7. Connection
7-1
Connection to Transceiver and Tuner
HC-1.5KAT Control Cable
230V AC Cord
Coax Jumper Cable
HL-2.5KFX
PTT Cable
ALC Cable
Transceiver
SEND/
STBY ALC ANT
◎ ◎ ◎
◎
Band Data Cable
Display/
connector name
Cable side
Connector
ACIN
①
AC200L
AC Power Cord
IEC3P Inlet
②
GND
200V 20A
③
AC200N
ALC
Transceiver
RF output (-) recitification
RCA-J
ALC socket
-10V max.
SEND
Transceiver
Short at TX
RCA-J
PTT relay
Open at RX
12V 40mA
TUNER
Tuning Control
Auto Tuner
Band tracking signal
DIN7J
②
GND
④
EVENT
HC-1.5KAT
⑦
FREQ
CONT socket
INPUT
UHF(SO239)
ANT
UHF(SO-239)
CONT
See Section 10. for details
D-SUB15R
D-SUB15P
Signal
To:
Description
Coax Antenna Cable
IEC3P
AC230V consent
RCA-P
ALC Output
RCA-P
PTT Input
DIN7P
PL259
HL-2.5KFX side
Band Data
Connector and Cable List
Band data terminal
of transceiver
Antenna or Tuner
Input
ANT of Transceiver Coax Cable
TRX
PL259
Antenna
11