25
(b)Multiple shutter
Multiple shutter via external trigger signal and external VD signal
*Operation like No.3, 6 above
(3)Restart / Reset
Restart / reset available via external VD signal
(Switching via rear panel DIP SW, Initial OFF)
Notes:
*The exposure-time (shutter-speed) is determined by external VD
interval. **Enabled when rear-panel DIP SW OFF. ***Provide
Consecutive HD.
[Partial scan]
(1)Operation mode
No
Scan mode
Sync
Reset
E-shutter
Normal
E-shutter
RTS
1
Non-reset
Enabled
(Option)
Enabled
2
V-reset
Disabled
Enabled
(Option)
3
Consecutive
HD VD IN
Non-reset
Enabled
(Option)
Enabled
4
Consecutive
HD (VD) IN
V-reset
Disabled
Enabled
(Option)
5
Non-reset
Enabled
(Option)
Enabled
6
V-reset
Disabled
Enabled
(Option)
7
Consecutive
HD VD IN
Non-reset
Enabled
(Option)
Enabled
8
Consecutive
HD (VD) IN
V-reset
Disabled
Enabled
(Option)
9
Programmable
Consecutive
HD VD IN
Non-reset
Enabled
(Option)
Enabled
(Option)
Internal
1/2 partial
1/4 partial
Internal
(2)Reset mode
As shown in (1) above, non-reset and V-reset is available.
(Option: Doesn’t come as standard. Contact our dealer / distributor
for details)
(a)non-reset (E-shutter enabled)
VD doesn’t get reset after video readout. The interval of VD signal is
as follows.
1/2 partial
scan
1/4 partial
scan
1/60s non-
interlace
525H
525H
1/120s
interlace
262.5H
262.5H
(b)V-reset (E-shutter disabled)
VD does get reset after video readout. Under internal sync, the
interval of VD signal is as follows.
VIDEO OUT
Partial
A
Partial
B
Partial
C
VD Interval