Frequency
Horizontal (f
H
)
CS83
2
0B
15.734 kHz ± 2 %
CS83
2
0BC
15.625 kHz ± 2 %
Vertical (f
V
)
CS83
2
0B
2f
H
/525
CS83
2
0BC
2f
H
/625
Number of scanning lines
CS83
2
0B
525 lines
CS83
2
0BC
625 lines
Phase between HD/VD
The phase relation between HD
and VD should be as shown
below.
t
1
=0±5
µ
s t
2
=1/f
H
/2±5
µ
s
(13) Output signal
Clock pulse
The clock pulse is available, if
necessary.
Pulse level
2.5 Vp-p/high impedance
Frequency
CS83
2
0B
14.318181 MHz ± 100 ppm
CS83
2
0BC
14.1875 MHz ± 100 ppm
HD/VD pulses
Pulse level
4.5 Vp-p/high impedance
Interlace
2 : 1
Polarity
Negative
Pulse width
HD
CS83
2
0B
6.36 ± 0.1µs
CS83
2
0BC
6.41 ± 0.1µs
VD
CS83
2
0B
572 ± 1µs
CS83
2
0BC
480 ± 1µs
Frequency
Horizontal (f
H
)
CS83
2
0B
15.73426 kHz ± 2 Hz
CS83
2
0BC
15.625 kHz ± 2 Hz
Vertical (f
V
)
CS83
2
0B
2f
H
/525
CS83
2
0BC
2f
H
/625
(14) Sensitivity setting
The following modes can be set
using the panel selection switch.
(Factory setting ; FIX)
FIX (FIX Gain); Standard
sensitivity setting.
AGC (Automatic Gain Control)
MGC (Manual Gain Control)
(15) AGC
Operating range
Stabilized by AGC within 2 dB
for ± 6dB of the output signal
variation.
(16) MGC
Sensitivity can be set manually.
(17) Gamma correction
0.45/1.0 selectable
- 20 -
- 19 -
1st FIELD for EIA
2nd FIELD for EIA
2nd FIELD for CCIR
1st FIELD for CCIR
VD
or
R. R
HD