Tokyo Electronic CS3910H Operation Manual Download Page 12

 

for consecutive 2V or longer, regardless of which RTS mode is currently set in. The HD ex-sync 
operation is available, while the VD ex-sync is not. The double-speed scan doesn't work. 

 
 
Video Output Timing 
-1. Under FIX mode 

*The VD is output in sync with the next HD after light-exposure. 

 
 
-2. Under PULSE mode 

*The VD is output in sync with the next HD after light-exposure 
 

 
 
 
 
 
 
 
 
 

 
 
 
 
 
11

TRIG

CCD 

(Exposure)

 

VIDEO 

OUT

HD 

VD 

WEN 

TRIG 

CCD 

(Exposure) 

VIDEO 

OUT 

HD 

VD 

WEN 

Summary of Contents for CS3910H

Page 1: ...High resolution CCD Camera Model CS3910H Operation Manual TOKYO ELECTRONIC INDUSTRY CO LTD 2000 09 21 Version 1 2...

Page 2: ...his mark warns the user that improper use indicated with this mark may cause personal injuries 1 or material damages 2 against the user or people around him her Notes 1 Personal injuries mean wounds b...

Page 3: ...ody discontinue the use immediately In the event that grits small particles or any other foreign objects get inside do NOT try to continue to use the device To do so invites a fire or an electric shoc...

Page 4: ...e liquids inside the bottle etc may get into the chassis causing a fire or an electric shock accident Avoid Do NOT short circuit signal outputs Avoid short circuit of signal outputs Otherwise it may c...

Page 5: ...ng the camera with its inner parts circuits in wet condition may cause a damage or an electric shock accident RESTRICTION FOR USE Do not attempt irregular signal interface other than specified Under s...

Page 6: ...ata read out CCD featuring ultra high resolution 2 FEATURES 1 Ultra high Resolution CS3910H features an ultra high picture resolution through the adoption of a MEGA pixel CCD Total pixel counts 1 400...

Page 7: ...on 7 Double speed Scan Mode The double speed scanning 24 frame second is available by using mixed reading out scanning method to read each vertical 2 pixel out at the same timing 8 Partial scan Mode T...

Page 8: ...t 2 DATA OUT Connector Digital Data Output Terminal This terminal is for outputting video signal and HD VD and CLK in RS 644 format For connection with an image processing equipment 6 HOW TO MOUNT YOU...

Page 9: ...10R 12PB Manufactured by HIROSE DENKI Plug Cable side HR10A 10P 12S Manufactured by HIROSE DENKI 2 DATA OUT Connector Camera side DX10A 36S Connector Cable side DX30A 36P DX 36 CV 1 Cover DATA0 LSB D...

Page 10: ...ON ON Normal Shutter 1 OFF XXXX OFF ON ON XXXX OFF XXXX OFF RTS Pulse Mode OFF RTS Fix Mode 1 OFF ON Notes 1 Normal E shutter doesn t work under partial scan mode 2 Under RTS Random Trigger Shutter an...

Page 11: ...RTS Random Trigger Shutter mode when TRIG terminal voltage is in HIGH More than 1V and starts light exposure at the falling edge timing Under FIX mode the exposure time is controlled with inner DIP sw...

Page 12: ...e the VD ex sync is not The double speed scan doesn t work Video Output Timing 1 Under FIX mode The VD is output in sync with the next HD after light exposure 2 Under PULSE mode The VD is output in sy...

Page 13: ...is made more than one time before the readout signal input superposed images are output After video output it goes back into the normal operation shutter OFF if the TRIG terminal voltage stays in LOW...

Page 14: ...re readout individually This allows multiple image processing on a serial basis requiring only one image processor 13 Exposure TRIG Readout E VD CCD exposure VIDEO OUT HD SUB SG Phi VINH WEN TRIG CAME...

Page 15: ...while the VD ex sync operation is not The double speed scan doesn t work Screen Center 1 2 Readout Total Lines 1034 Lines Scanning Area 474 Lines 14 High speed Transfer Open Area 280 Lines Normal spe...

Page 16: ...g output 1 0V p p 75 ohm Unbalanced AGC Video signal output fluctuation of plus minus 2dB or less against standard subject illumination minus 6dB Enabled under normal mode only External input signal T...

Page 17: ...ulse mode Exposure time determined by pulse length Partial scan ON OFF selectable Initial factory setting OFF ON Screen center 1 2 readout Multiple shutter ON OFF selectable Initial factory setting OF...

Page 18: ...h Y axis Relative response 10 TIMING CHART 10 1 Analog output 1 H rate 1 CLK 49 4ns 20 245MHz H SYNC A 2 47 micro s HBL B 15 61 micro s Front porch C 4 94 micro s Back porch D 8 20 micro s DATA E 64 2...

Page 19: ...scan mode A 3H A 2H B 14H B 7H C 9H C 4H D 2H D 1H E 1030H E 515H F 1044H 12Hz F 522H 24Hz ENLARGED VIEW V RATE A 1 Under normal mode VD VIDEO H rate a 79 82 micro s V SYNC b 4 94 micro s 2 Under RTS...

Page 20: ...VDS Driver output voltage Plus minus 350mV Differential output 100 ohm HD DATA CLK Total clock counts 1616CLK 1H DATA counts 1300CLK 1H CLK 49 4ns V rate phase Same as one in analog timing chart HD VD...

Page 21: ...t timing 1 Under normal E shutter operation 2 Under RTS operation 2 1 Fixed speed mode 2 2 Pulse mode 20 CCD Exposure Video Output WEN TRIG CCD Exposure Video Output HD VD WEN TRIG CCD Exposure Video...

Page 22: ...11 EXTERNAL VIEW DRAWING 21...