24
Continued from the front chart
Sub-harmonic content rate
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
1st harmonic of phase A voltage
1st harmonic of phase B voltage
1st harmonic of phase C voltage
21st harmonic of phase B voltage
21st harmonic of phase C voltage
21st harmonic of phase A voltage
......
Phase A voltage
harmonic data
Phase B voltage
harmonic data
Phase C voltage
harmonic data
Phase A current
harmonic data
Phase B current
harmonic data
Phase C current
harmonic data
Phase A voltage harmonic data block
Phase B voltage harmonic data block
Phase C voltage harmonic data block
Phase A current harmonic data block
Phase B current harmonic data block
Phase C current harmonic data block
......
......
......
21st harmonic of phase A current
1st harmonic of phase A current
1st harmonic of phase C current
21st harmonic of phase C current
21st harmonic of phase B current
1st harmonic of phase B current
......
......
0x020A0115
0x020A01FF
0x020A0201
0x020A0215
0x020A02FF
0x020A0301
0x020A0315
0x020A03FF
0x020B0101
0x020B0115
0x020B01FF
0x020B0201
0x020B0215
0x020B02FF
0x020B0301
0x0205FF00
0x020B03FF
2
2
3
2
2
2
2
2
2
2
2
2
2
2
2
2
2
0x020A0101
2
1
21
1
1
21
1
1
21
1
1
21
1
1
21
1
1
21
1
23
VIII. DLT645 communication description
8.1 Overview
8.2 DLT645 communication address correspondence table
①
This meter is not designed according to the national grid meter specifications. Therefore, only part of the
electrical parameters can be read through the DLT645 protocol. For the specific read parameters, please
refer to the correspondence address table below;
②
The communication data of the national grid is the primary side data without PT and CT. Therefore,
in order to prevent the read data from overflowing, the data of this meter read through DLT645
should be the secondary side data;
③
For specific DLT645 communication protocol, please refer to "DLT645-2007 Multi-function
Energy Meter Communication Protocol"
No.
Parameter
Communication Add Response bytes
Instantaneous electrical parameters
Instantaneous
electrical
parameters
Cumulative
function
Response qty Remark
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
Phase B current
Phase C current
Phase A current
Phase B voltage
Phase A voltage
Phase C voltage
Voltage data block
Current data block
Combined active power
Phase A active power
Phase B active power
Phase C active power
Active power data block
Combined reactive power
Phase A reactive power
Phase B reactive power
Phase C reactive power
Combined apparent power
Phase A apparent power
Phase B apparent power
Phase C apparent power
Apparent power data block
Power factor data block
Positive active integrated
electric energy
Reverse active integrated
electric energy
Active integrated electric energy
Grid frequency
Phase A power factor
Phase B power factor
Phase C power factor
Combined power factor
Reactive power data block
0x02010200
0x02010300
0x0201FF00
0x02020100
0x02020200
0x02020300
0x0202FF00
0x02030000
0x02030100
0x02030200
0x02030300
0x0203FF00
0x02040000
0x02040100
0x02040200
0x02040300
0x0204FF00
0x02050000
0x02050100
0x02050200
0x02050300
0x0205FF00
0x02060000
0x02060100
0x02060200
0x02060300
0x0206FF00
0x02800002
0x00000000
0x00010000
0x00020000
2
2
2
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
4
4
4
1
1
3
1
1
1
3
1
1
1
1
4
1
1
1
1
4
1
1
1
1
4
1
1
1
1
4
1
1
1
1
0x02010100
2
1